Difference between revisions of "D2O material effect on the neutron asymmetry"
Jump to navigation
Jump to search
(Created page with 'File:Neutron_asymmetry.pdf') |
|||
(10 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
[[File:Neutron_asymmetry.pdf]] | [[File:Neutron_asymmetry.pdf]] | ||
+ | |||
+ | |||
+ | == MCNPX Results == | ||
+ | A simulation was done using MCNPX to see how neutron scattering impacts asymmetry measurements. The setup is shown below. Neutrons were created inside a bottle of D2O and given an initial direction towards the 0 degree detector. The size of the target and detectors are the actual size used in the experiment. The distance between the target and each detector is 1 meter. | ||
+ | ---- | ||
+ | [[File:MCNPX_8_3_pg1.jpg | 600px]] | ||
+ | ---- | ||
+ | A neutron energy distribution was put into MCNPX based off the actual energy distribution from the experimental data. | ||
+ | ---- | ||
+ | [[File:MCNPX_8_3_pg2.jpg | 800px]] | ||
+ | ---- | ||
+ | The asymmetry results are shown below. | ||
+ | ---- | ||
+ | [[File:MCNPX_8_3_pg3.jpg | 800px]] | ||
+ | |||
+ | [https://wiki.iac.isu.edu/index.php/PhotoFission_with_Polarized_Photons_from_HRRL back] |
Latest revision as of 19:06, 3 August 2011
MCNPX Results
A simulation was done using MCNPX to see how neutron scattering impacts asymmetry measurements. The setup is shown below. Neutrons were created inside a bottle of D2O and given an initial direction towards the 0 degree detector. The size of the target and detectors are the actual size used in the experiment. The distance between the target and each detector is 1 meter.
A neutron energy distribution was put into MCNPX based off the actual energy distribution from the experimental data.
The asymmetry results are shown below.