D2O material effect on the neutron asymmetry: Difference between revisions
Jump to navigation
Jump to search
Created page with 'File:Neutron_asymmetry.pdf' |
|||
| (10 intermediate revisions by the same user not shown) | |||
| Line 1: | Line 1: | ||
[[File:Neutron_asymmetry.pdf]] | [[File:Neutron_asymmetry.pdf]] | ||
== MCNPX Results == | |||
A simulation was done using MCNPX to see how neutron scattering impacts asymmetry measurements. The setup is shown below. Neutrons were created inside a bottle of D2O and given an initial direction towards the 0 degree detector. The size of the target and detectors are the actual size used in the experiment. The distance between the target and each detector is 1 meter. | |||
---- | |||
[[File:MCNPX_8_3_pg1.jpg | 600px]] | |||
---- | |||
A neutron energy distribution was put into MCNPX based off the actual energy distribution from the experimental data. | |||
---- | |||
[[File:MCNPX_8_3_pg2.jpg | 800px]] | |||
---- | |||
The asymmetry results are shown below. | |||
---- | |||
[[File:MCNPX_8_3_pg3.jpg | 800px]] | |||
[https://wiki.iac.isu.edu/index.php/PhotoFission_with_Polarized_Photons_from_HRRL back] | |||
Latest revision as of 19:06, 3 August 2011
MCNPX Results
A simulation was done using MCNPX to see how neutron scattering impacts asymmetry measurements. The setup is shown below. Neutrons were created inside a bottle of D2O and given an initial direction towards the 0 degree detector. The size of the target and detectors are the actual size used in the experiment. The distance between the target and each detector is 1 meter.
A neutron energy distribution was put into MCNPX based off the actual energy distribution from the experimental data.
The asymmetry results are shown below.