First I change the power supply for HAMAMATSU PMT to the new 2 channel one C.A.E.N N471)
+
First I change the power supply for HAMAMATSU PMT to the new 2 channel one C.A.E.N N471
  
  

Revision as of 16:23, 10 May 2011

Go Back


continue...the same set up as before, the distances are the same:

Detector1.png


First I change the power supply for HAMAMATSU PMT to the new 2 channel one C.A.E.N N471


The powers are:

PS1 and PS2:  -1000 V (the old 2-channel TENNELEC TC952)
n's: -1100 V (the new 2-channel C.A.E.N N471)


The thresholds were:

PS1 and PS2:  -80 mV
n's: -60 mV


Let see what we have. First he CF-243 source is far far away (sealed in the safe):

counts/min (1 min test) counts/min (1 min test) counts/min (5 min test) counts/min (5 min test) avg counts/min
PS1 187 160 166
PS2 187 170 180.4
PS1+PS2
n's 205 204 201.2