Difference between revisions of "HRRL 03-17-2011"
Jump to navigation
Jump to search
(→Q1) |
|||
Line 66: | Line 66: | ||
=== 42 mA, Positive Current, X projection === | === 42 mA, Positive Current, X projection === | ||
− | emit=0. | + | emit=0.389 +- 0.001 mm*mrad, emit_norm=10.658 +- 0.034 mm*mrad |
− | beta=1. | + | beta=1.28826 +- 0.00004, alpha=0.9378 +-0.0007 |
[[File:HRRL 03-17-2011_Results_Q1_42mA_Pos_SupGau_X.png | 300 px]] | [[File:HRRL 03-17-2011_Results_Q1_42mA_Pos_SupGau_X.png | 300 px]] | ||
Line 75: | Line 75: | ||
=== 42 mA, Negative Current, Y projection === | === 42 mA, Negative Current, Y projection === | ||
+ | |||
+ | emit=0.269 +- 0.001 mm*mrad, emit_norm=7.370 +- 0.024 mm*mrad | ||
+ | |||
+ | beta=0.9271 +- 0.0001, alpha=0.1922 +-0.0005 | ||
[[File:HRRL 03-17-2011_Results_Q1_42mA_Pos_SupGau_Y.png | 300 px]] | [[File:HRRL 03-17-2011_Results_Q1_42mA_Pos_SupGau_Y.png | 300 px]] |
Revision as of 16:58, 13 April 2011
Accelerator Tuning
Good Tune Used for good Scan
By Dr. Kim
Calibration
image | OTR image | cal_h (mm/px) | cal_v (mm/px) |
0.04308 | 0.04204 | ||
0.04320 | 0.04228 | ||
0.04349 | 0.04181 | ||
0.04323 | 0.04196 | ||
0.04337 | 0.04212 | ||
mean (mm/px) | mean (mm/px) | ||
Results
Q1
42 mA, Positive Current, X projection
emit=0.389 +- 0.001 mm*mrad, emit_norm=10.658 +- 0.034 mm*mrad
beta=1.28826 +- 0.00004, alpha=0.9378 +-0.0007
42 mA, Negative Current, Y projection
emit=0.269 +- 0.001 mm*mrad, emit_norm=7.370 +- 0.024 mm*mrad
beta=0.9271 +- 0.0001, alpha=0.1922 +-0.0005