Revision as of 23:34, 17 March 2011

Accelerator Tuning

Accelerator Settings (Yujong Tune 11 am)
Solenoid 1 6.8 A
Solenoid 2 10.4 A
Horzontal In +0.4 A
Vertical In -0.2 A
Horzontal out -1.4A
Vertical Out -0.5 A

Good Tune Used for good Scan

By Dr. Kim

Solenoid 1 6.8 A
Solenoid 2 10.4 A
Gun Ver -0.2 A
Gun Hor +0.4 A
Output Hor -1.4A
Output Ver -0.5 A
Gun HV +9.75 (Knob Setting)
Gun Grid Voltage 5.25 (Knob Setting)
RF frequency 2855.816 MHz
Modulator HV Power Supply 4.42 (Knob Setting)
RF macro Pulse Length (FWHM) 200 ns
Peak Current on FC 37.2 mAmps
Scope on FC Scope image of good Accelarator setting by Dr. Kim Mar 17 2011.png
e- Beam Energy 14 MeV