Difference between revisions of "HRRL OTR Test Mar 3rd 2011"

From New IAC Wiki
Jump to navigation Jump to search
Line 321: Line 321:
 
== Field Emission ==
 
== Field Emission ==
  
HV on, RF on  
+
HV on, RF on  
  
 
[[File:HRRL_Test_Mar_3rd_2001_FIled_Emission_Cehck_HV_on_Filament_on_RF_on.jpg | 400 px]]
 
[[File:HRRL_Test_Mar_3rd_2001_FIled_Emission_Cehck_HV_on_Filament_on_RF_on.jpg | 400 px]]
  
HV off, RF on  
+
HV off, RF on  
  
 
[[File:HRRL_Test_Mar_3rd_2001_FIled_Emission_Cehck_HV_off_Filament_on_RF_on.jpg | 400 px]]
 
[[File:HRRL_Test_Mar_3rd_2001_FIled_Emission_Cehck_HV_off_Filament_on_RF_on.jpg | 400 px]]
  
HV off, RF off  
+
HV off, RF off  
  
 
[[File:HRRL_Test_Mar_3rd_2001_FIled_Emission_Cehck_HV_off_Filament_on_RF_off.jpg | 400 px]]
 
[[File:HRRL_Test_Mar_3rd_2001_FIled_Emission_Cehck_HV_off_Filament_on_RF_off.jpg | 400 px]]
  
HV on, Filament on, RF on, Valve closed
+
HV on, Filament on, RF on, Valve closed
  
 
[[File:HRRL_Test_Mar_3rd_2001_FIled_Emission_Cehck_HV_on_Filament_on_RF_on_valve_closed.jpg | 400 px]]
 
[[File:HRRL_Test_Mar_3rd_2001_FIled_Emission_Cehck_HV_on_Filament_on_RF_on_valve_closed.jpg | 400 px]]

Revision as of 04:05, 6 March 2011

Preparation

JAI Camera Setup

Target in:

HRRL OTR Test Mar 3rd 2011 JAI Camera Setup 1.jpg HRRL OTR Test Mar 3rd 2011 JAI Camera Setup 2.jpg


Target out:

HRRL OTR Test Mar 3rd 2011 JAI Camera Setup Target Out 1.jpg


Target in after shielded:

HRRL OTR Test Mar 3rd 2011 JAI Camera Setup shielded target in 1.jpg

Objectives

Determined if the steering magnets of the gun are connected to power supply

1. Physically check looking at wires.

2. Change currents on the steering magnet, and observe position of the beam spot. If changes then, connected.

Tune beam using Linac optics only

Chad will tune up the beam using steering elements which are within the HRRL Linac only.

Determined if the OTR target is centered on the beam line

With all beam line magnets off, observe the beam spot at the OTR target. If the beam is centered on the OTR target, then OTR target MAY be centered on the beam line.

Polarization test

Insert a polarizer film. Take several picture for different orientations without changing beam properties.

Angel is measured with respect to:

Polarizer Angel Iamge
200 px 200 px

Determined if the quads are centered on the beam line

The power supplies for ALL quads should be off.

Turn on Quad closesst to HRRL

If the beam deflects, try to align quad so there is no deflection

Turn on Quad closest to OTR target

If the beam deflects, try to align quad so there is no deflection


Run

Field Emission Check

Peak Current (mA): 160

Rep Rate (Hz): 6

Pulse width (ns): 200

HV on, Filament on, RF on

HRRL Test Mar 3rd 2001 FIled Emission Cehck HV on Filament on RF on.jpg

HV off, Filament on, RF on

HRRL Test Mar 3rd 2001 FIled Emission Cehck HV off Filament on RF on.jpg

HV off, Filament on, RF off

HRRL Test Mar 3rd 2001 FIled Emission Cehck HV off Filament on RF off.jpg

HV on, Filament on, RF off

HRRL Test Mar 3rd 2001 FIled Emission Cehck HV on Filament on RF off.jpg



HV on, Filament on, RF on, Valve closed

HRRL Test Mar 3rd 2001 FIled Emission Cehck HV on Filament on RF on valve closed.jpg

HV off, Filament on, RF on, Valve closed

HRRL Test Mar 3rd 2001 FIled Emission Cehck HV off Filament on RF on valve closed.jpg

HV on, Filament on, RF off, Valve closed

HRRL Test Mar 3rd 2001 FIled Emission Cehck HV on Filament on RF off valve closed.jpg

HV off, Filament on, RF off, Valve closed

HRRL Test Mar 3rd 2001 FIled Emission Cehck HV off Filament on RF off valve closed.jpg

Conclusion

When the HV is off, there were not any electrons from filament. We still see back ground light. This due the the dark current, emitted from the cavity (field emission).

Estimation of How Much off

Rep Rate (Hz): 6

Pulse width (ns): 200

Take at least 3 images for each setting below.

The goal is to estimate how far things may be misaligned. Several assumption will be made.

Tuned for Max transmision to FC Just by steering Magnets

Peak Current (mA): 160


HRRL OTR Test Mar 3rd 2011Tuned for Max transmision to FC Just by steering Magnets.jpg

Tuned for Max transmision to FC by using quads and steering Magnets

Using 1st Triplets

Peak Current (mA): 160

HRRL OTR Test Mar 3rd 2011Tuned for Max transmision to FC by steering Magnets and quads 1st triplet.jpg


Using 2nd Triplets

Peak Current (mA): 160

HRRL OTR Test Mar 3rd 2011Tuned for Max transmision to FC by steering Magnets and quads 2nd triplet.jpg


Using Both Triplets

Peak Current (mA): 160

HRRL OTR Test Mar 3rd 2011Tuned for Max transmision to FC by steering Magnets and quads both triplet.jpg

Tuned for Min Quad deflection

Find the spot that when we change quad currents, center of the beam spot does not change or change the lest.

Rep Rate (Hz): 6

Pulse width (ns): 200

Quqads off

Peak Current (mA): 35

Quads off:

HRRL OTR Test Mar 3rd 2011 Tuned for Min Quad deflection spot quads off.jpg

1st quad of the 1st triplet on

1st quad of the 1st triplet power supply at (A): 2

HRRL OTR Test Mar 3rd 2011 Tuned for Min Quad deflection spot 1st quad of 1st Triplet power supply at 2Amp.jpg

1st quad of the 1st triplet power supply at (A): 4

HRRL OTR Test Mar 3rd 2011 Tuned for Min Quad deflection spot 1st quad of 1st Triplet power supply at 4Amp.jpg

1st quad of the 1st triplet power supply at (A): 6

HRRL OTR Test Mar 3rd 2011 Tuned for Min Quad deflection spot 1st quad of 1st Triplet power supply at 6Amp.jpg

1st quad of the 1st triplet power supply at (A): 8

HRRL OTR Test Mar 3rd 2011 Tuned for Min Quad deflection spot 1st quad of 1st Triplet power supply at 8Amp.jpg

1st quad of the 1st triplet power supply at (A): 10

HRRL OTR Test Mar 3rd 2011 Tuned for Min Quad deflection spot 1st quad of 1st Triplet power supply at 10Amp.jpg



2nd quad of the 1st triplet on

2nd quad of the 1st triplet power supply at (A): 2

HRRL OTR Test Mar 3rd 2011 Tuned for Min Quad deflection spot 2nd quad of 1st Triplet power supply at 2Amp.jpg

2nd quad of the 1st triplet power supply at (A): 4

HRRL OTR Test Mar 3rd 2011 Tuned for Min Quad deflection spot 2nd quad of 1st Triplet power supply at 4Amp.jpg

2nd quad of the 1st triplet power supply at (A): 6

HRRL OTR Test Mar 3rd 2011 Tuned for Min Quad deflection spot 2nd quad of 1st Triplet power supply at 6Amp.jpg

2nd quad of the 1st triplet power supply at (A): 8

HRRL OTR Test Mar 3rd 2011 Tuned for Min Quad deflection spot 2nd quad of 1st Triplet power supply at 8Amp.jpg

2nd quad of the 1st triplet power supply at (A): 10

HRRL OTR Test Mar 3rd 2011 Tuned for Min Quad deflection spot 2nd quad of 1st Triplet power supply at 10Amp.jpg

Tune on center of Target

Rep Rate (Hz): 6 Pulse width (ns): 200 Peak Current (mA): 120

Tuned on center of the target:

HRRL OTR Test Mar 3rd 2011 Tuned on center of Target Beam On.jpg


Rf on, HV off (for back ground subtraction):

HRRL OTR Test Mar 3rd 2011 Tuned on center of Target HV Off RF On for bg subtraction.jpg


No beam, light is on:

HRRL OTR Test Mar 3rd 2011 Tuned on center of Target No Beam.jpg

OTR Check Polarization

Pulse width (FMHM): 200 ns

Peak Current: 160 mA

Camera focused at infinity.

No polarizer

Accelerator off, back ground

HRRL OTR Test Mar 3rd 2011 OTR Check Polarization No polarizer Back Ground.jpg

50 Hz Rep Rate

HRRL OTR Test Mar 3rd 2011 OTR Check Polarization No polarizer 50Hz 1.jpg HRRL OTR Test Mar 3rd 2011 OTR Check Polarization No polarizer 50Hz 2.jpg

291 Hz Rep Rate

HRRL OTR Test Mar 3rd 2011 OTR Check Polarization No polarizer 291Hz 1.jpg HRRL OTR Test Mar 3rd 2011 OTR Check Polarization No polarizer 291Hz 2.jpg

Polarization of the Polarizer Parallel to the Beam Line Direction

HRRL OTR Test Mar 3rd 2011 OTR Check Polarization polarizer Parellel to BeamLine 80Hz 1.jpg HRRL OTR Test Mar 3rd 2011 OTR Check Polarization polarizer Parellel to BeamLine 80Hz 2.jpg


Polarization of the Polarizer Perpendicular to the Beam Line Direction

HRRL OTR Test Mar 3rd 2011 OTR Check Polarization perpendicular Parellel to BeamLine 80Hz 1.jpg HRRL OTR Test Mar 3rd 2011 OTR Check Polarization perpendicular Parellel to BeamLine 80Hz 2.jpg

Time Slice Study of the OTR

Take pictures at different time slices from the trigger.

This means take a picture and then delay the trigger pulse to the camera relative to the RF. Perhaps the light has a time structure.

Rep Rate (Hz): 6

Pulse width (ns): 200

160 mA peak Current

Peak Current (mA): 160


HRRL OTR Test Mar 3rd 2011 Time Slice Study Delayed 160mA 0ns.jpg HRRL OTR Test Mar 3rd 2011 Time Slice Study Delayed 160mA 1ns.jpg HRRL OTR Test Mar 3rd 2011 Time Slice Study Delayed 160mA 2ns.jpg HRRL OTR Test Mar 3rd 2011 Time Slice Study Delayed 160mA 4ns.jpg HRRL OTR Test Mar 3rd 2011 Time Slice Study Delayed 160mA 8ns.jpg HRRL OTR Test Mar 3rd 2011 Time Slice Study Delayed 160mA 16ns.jpg HRRL OTR Test Mar 3rd 2011 Time Slice Study Delayed 160mA 32ns.jpg HRRL OTR Test Mar 3rd 2011 Time Slice Study Delayed 160mA 64ns.jpg HRRL OTR Test Mar 3rd 2011 Time Slice Study Delayed 160mA 96ns.jpg HRRL OTR Test Mar 3rd 2011 Time Slice Study Delayed 160mA 127ns.jpg



105 mA peak Current

Peak Current (mA): 105


HRRL OTR Test Mar 3rd 2011 Time Slice Study Delayed 105mA 0ns.jpg HRRL OTR Test Mar 3rd 2011 Time Slice Study Delayed 105mA 1ns.jpg HRRL OTR Test Mar 3rd 2011 Time Slice Study Delayed 105mA 2ns.jpg HRRL OTR Test Mar 3rd 2011 Time Slice Study Delayed 105mA 4ns.jpg HRRL OTR Test Mar 3rd 2011 Time Slice Study Delayed 105mA 8ns.jpg HRRL OTR Test Mar 3rd 2011 Time Slice Study Delayed 105mA 16ns.jpg HRRL OTR Test Mar 3rd 2011 Time Slice Study Delayed 105mA 32ns.jpg HRRL OTR Test Mar 3rd 2011 Time Slice Study Delayed 105mA 64ns.jpg HRRL OTR Test Mar 3rd 2011 Time Slice Study Delaye 105mAd 96ns.jpg HRRL OTR Test Mar 3rd 2011 Time Slice Study Delayed 105mA 127ns.jpg

Far field

Now return the camera trigger back to the original location in time. Focus at infinity and try to observe polarization.


Report

Field Emission

HV on, RF on

HRRL Test Mar 3rd 2001 FIled Emission Cehck HV on Filament on RF on.jpg

HV off, RF on

HRRL Test Mar 3rd 2001 FIled Emission Cehck HV off Filament on RF on.jpg

HV off, RF off

HRRL Test Mar 3rd 2001 FIled Emission Cehck HV off Filament on RF off.jpg

HV on, Filament on, RF on, Valve closed

HRRL Test Mar 3rd 2001 FIled Emission Cehck HV on Filament on RF on valve closed.jpg

When the HV is off, there were not any electrons from filament. We still see back ground light. This light was gone when the RF was turned off or vacuum valve (between screen and gun) was closed. So, this back ground light was due the the dark current that emitted from the cavity (field emission).