Difference between revisions of "Lab 4 RS"
Line 88: | Line 88: | ||
==Compare the theoretical and experimentally measured break frequencies. (5 pnts)== | ==Compare the theoretical and experimentally measured break frequencies. (5 pnts)== | ||
+ | |||
+ | Theoretical break frequency: <math>12.13\ \mbox{kHz}</math> | ||
+ | |||
+ | The fit line equation from the plot above is <math>\ y=-1.14+0.9101\cdot x</math>. | ||
+ | From intersection point of line with x-axis we find: | ||
+ | |||
+ | :<math>\mbox{log}(f_{exper})=\frac{1.14}{0.9101} = 1.252</math> | ||
+ | |||
+ | :<math>f_{exp} = 10^{1.252} = 17.86\ \mbox{kHz} </math> | ||
+ | |||
+ | |||
+ | The error is: | ||
+ | |||
+ | <math>Error = \left| \frac{f_{exp} - f_{theor}}{f_{theor}} \right| = \left| \frac{17.86 - 12.13}{12.13} \right|= 32.08\ %</math> | ||
+ | |||
+ | Error is pretty big. Probably is something wrong with RC measurements. | ||
==Calculate and expression for <math>\frac{V_{out}}{ V_{in}}</math> as a function of <math>\nu</math>, <math>R</math>, and <math>C</math>.(5 pnts)== | ==Calculate and expression for <math>\frac{V_{out}}{ V_{in}}</math> as a function of <math>\nu</math>, <math>R</math>, and <math>C</math>.(5 pnts)== |
Revision as of 06:58, 27 January 2011
- RC High-pass filter
1-50 kHz filter (20 pnts)
1. Design a high-pass RC filter with a break point between 1-50 kHz. The break point is the frequency at which the filter's attenuation of the AC signal goes to 0(not passed). For a High pass filter, AC signals with a frequency below the 1-50 kHz range will be attenuated .
- To design low-pass RC filter I had:
So
2. Now construct the circuit using a non-polar capacitor.
3. Use a sinusoidal variable frequency oscillator to provide an input voltage to your filter.
4. Measure the input and output voltages for at least 8 different frequencies which span the frequency range from 1 Hz to 1 MHz.
0.1 | |||
1.0 | |||
2.0 | |||
3.0 | |||
4.0 | |||
5.0 | |||
6.0 | |||
7.0 | |||
8.0 | |||
9.0 | |||
10.0 | |||
11.0 | |||
12.0 | |||
15.0 | |||
20.0 | |||
30.0 | |||
40.0 | |||
50.0 | |||
100.0 | |||
200.0 |
5. Graph the -vs-
phase shift (10 pnts)
- measure the phase shift between and
Questions
Compare the theoretical and experimentally measured break frequencies. (5 pnts)
Theoretical break frequency:
The fit line equation from the plot above is
. From intersection point of line with x-axis we find:
The error is:
Error is pretty big. Probably is something wrong with RC measurements.
Calculate and expression for as a function of , , and .(5 pnts)
We have:
Dividing second equation into first one we get the voltage gain:
And we are need the real part:
Compare the theoretical and experimental value for the phase shift . (5 pnts)
The experimental phase shift is
The theoretical phase shift is
Sketch the phasor diagram for , , , and . Put the current along the real voltage axis. (30 pnts)
What is the phase shift for a DC input and a very-high frequency input?(5 pnts)
Because a DC circuit doesn't have any oscillation there are no any phase shift.
Calculate and expression for the phase shift as a function of , , and graph -vs . (20 pnts)
From the phasor diagram above (question 4) the angle between vectors
and given by