Difference between revisions of "Ribbon Cable Attenuation Measurements"
Jump to navigation
Jump to search
| (8 intermediate revisions by the same user not shown) | |||
| Line 1: | Line 1: | ||
[http://wiki.iac.isu.edu/index.php/PhotoFission_with_Polarized_Photons_from_HRRL Go Back] | [http://wiki.iac.isu.edu/index.php/PhotoFission_with_Polarized_Photons_from_HRRL Go Back] | ||
| + | |||
| + | =Attenuation of Ribbon Cable measurements= | ||
==Experimental Set Up== | ==Experimental Set Up== | ||
| Line 28: | Line 30: | ||
<math>V_2</math> - with Ribbon Cable | <math>V_2</math> - with Ribbon Cable | ||
| − | ==Pictures | + | ==Pictures about change of pulse shape== |
{| border="1" cellpadding="20" cellspacing="0" | {| border="1" cellpadding="20" cellspacing="0" | ||
| Line 47: | Line 49: | ||
| [[File:30ns before.JPG | 400 px]] || [[File:30ns after.JPG | 400 px]] | | [[File:30ns before.JPG | 400 px]] || [[File:30ns after.JPG | 400 px]] | ||
|}<br><br> | |}<br><br> | ||
| + | |||
| + | |||
| + | =Signal Delay in Ribbon Cable measurements= | ||
| + | |||
| + | ==Experimental Set Up== | ||
| + | |||
| + | {| border="1" cellpadding="20" cellspacing="0" | ||
| + | | setup without Ribbon Cable|| setup with Ribbon Cable | ||
| + | |- | ||
| + | | [[File:Setup_2signal_before.JPG | 400 px]] || [[File:Setup_2signal_after.JPG | 400 px]] | ||
| + | |}<br><br> | ||
| + | |||
| + | ==Measurements== | ||
| + | |||
| + | {| border="1" cellpadding="20" cellspacing="0" | ||
| + | | 2 pulses without Ribbon Cable|| 2 pulses with Ribbon Cable | ||
| + | |- | ||
| + | | [[File:100ns delay before.JPG | 400 px]] || [[File:100ns delay after.JPG | 400 px]] | ||
| + | |}<br><br> | ||
| + | |||
| + | We have about 170 ns delay of signal in Ribbon Cable for 100 ns pulse. | ||
| + | For other pulse width the delay is about the same. | ||
[http://wiki.iac.isu.edu/index.php/PhotoFission_with_Polarized_Photons_from_HRRL Go Back] | [http://wiki.iac.isu.edu/index.php/PhotoFission_with_Polarized_Photons_from_HRRL Go Back] | ||
Latest revision as of 22:27, 19 January 2011
Attenuation of Ribbon Cable measurements
Experimental Set Up
| setup without Ribbon Cable | setup with Ribbon Cable |
Measurements
| Pulse width | Attenuation, % | Comments | ||
| 10 % | ||||
| 16 % | ||||
| 40 % | see pictures about change of pulse shape | |||
| 44 % | see pictures about change of pulse shape | |||
| 55 % | see pictures about change of pulse shape |
- without Ribbon Cable - with Ribbon Cable
Pictures about change of pulse shape
| pulse without Ribbon Cable | pulse with Ribbon Cable |
| pulse without Ribbon Cable | pulse with Ribbon Cable |
| pulse without Ribbon Cable | pulse with Ribbon Cable |
Signal Delay in Ribbon Cable measurements
Experimental Set Up
| setup without Ribbon Cable | setup with Ribbon Cable |
Measurements
| 2 pulses without Ribbon Cable | 2 pulses with Ribbon Cable |
We have about 170 ns delay of signal in Ribbon Cable for 100 ns pulse. For other pulse width the delay is about the same.