| + | =Attenuation of Ribbon Cable measurements=  | ||
==Experimental Set Up==  | ==Experimental Set Up==  | ||
| Line 6: | Line 8: | ||
| setup without Ribbon Cable|| setup with Ribbon Cable  | | setup without Ribbon Cable|| setup with Ribbon Cable  | ||
|-  | |-  | ||
| − | | [[Setup before.JPG | 400 px]] || [[Setup after.JPG | 400 px]]    | + | | [[File:Setup before.JPG | 400 px]] || [[File:Setup after.JPG | 400 px]]    | 
|}<br><br>  | |}<br><br>  | ||
| Line 28: | Line 30: | ||
  <math>V_2</math> - with Ribbon Cable  |   <math>V_2</math> - with Ribbon Cable  | ||
| − | ==Pictures==  | + | ==Pictures about change of pulse shape==  | 
{| border="1"  cellpadding="20" cellspacing="0"  | {| border="1"  cellpadding="20" cellspacing="0"  | ||
| Line 47: | Line 49: | ||
| [[File:30ns before.JPG | 400 px]] || [[File:30ns after.JPG | 400 px]]    | | [[File:30ns before.JPG | 400 px]] || [[File:30ns after.JPG | 400 px]]    | ||
|}<br><br>  | |}<br><br>  | ||
| + | |||
| + | |||
| + | =Signal Delay in Ribbon Cable measurements=  | ||
| + | |||
| + | ==Experimental Set Up==  | ||
| + | |||
| + | {| border="1"  cellpadding="20" cellspacing="0"  | ||
| + | | setup without Ribbon Cable|| setup with Ribbon Cable  | ||
| + | |-  | ||
| + | | [[File:Setup_2signal_before.JPG | 400 px]] || [[File:Setup_2signal_after.JPG | 400 px]]   | ||
| + | |}<br><br>  | ||
| + | |||
| + | ==Measurements==  | ||
| + | |||
| + | {| border="1"  cellpadding="20" cellspacing="0"  | ||
| + | | 2 pulses without Ribbon Cable|| 2 pulses with Ribbon Cable  | ||
| + | |-  | ||
| + | | [[File:100ns delay before.JPG | 400 px]] || [[File:100ns delay after.JPG | 400 px]]   | ||
| + | |}<br><br>  | ||
| + | |||
| + |  We have about 170 ns delay of signal in Ribbon Cable for 100 ns pulse.   | ||
| + |  For other pulse width the delay is about the same.  | ||
[http://wiki.iac.isu.edu/index.php/PhotoFission_with_Polarized_Photons_from_HRRL Go Back]  | [http://wiki.iac.isu.edu/index.php/PhotoFission_with_Polarized_Photons_from_HRRL Go Back]  | ||
Latest revision as of 22:27, 19 January 2011
Attenuation of Ribbon Cable measurements
Experimental Set Up
| setup without Ribbon Cable | setup with Ribbon Cable | 
Measurements
| Pulse width | Attenuation, % | Comments | ||
| 10 % | ||||
| 16 % | ||||
| 40 % | see pictures about change of pulse shape | |||
| 44 % | see pictures about change of pulse shape | |||
| 55 % | see pictures about change of pulse shape | 
- without Ribbon Cable - with Ribbon Cable
Pictures about change of pulse shape
| pulse without Ribbon Cable | pulse with Ribbon Cable | 
| pulse without Ribbon Cable | pulse with Ribbon Cable | 
| pulse without Ribbon Cable | pulse with Ribbon Cable | 
Signal Delay in Ribbon Cable measurements
Experimental Set Up
| setup without Ribbon Cable | setup with Ribbon Cable | 
Measurements
| 2 pulses without Ribbon Cable | 2 pulses with Ribbon Cable | 
We have about 170 ns delay of signal in Ribbon Cable for 100 ns pulse. For other pulse width the delay is about the same.