Attenuation of Ribbon Cable measurements
Experimental Set Up
| setup without Ribbon Cable | setup with Ribbon Cable |
Measurements
| Pulse width | Attenuation, % | Comments | ||
| 10 % | ||||
| 16 % | ||||
| 40 % | see pictures about change of pulse shape | |||
| 44 % | see pictures about change of pulse shape | |||
| 55 % | see pictures about change of pulse shape |
- without Ribbon Cable - with Ribbon Cable
Pictures about change of pulse shape
| pulse without Ribbon Cable | pulse with Ribbon Cable |
| pulse without Ribbon Cable | pulse with Ribbon Cable |
| pulse without Ribbon Cable | pulse with Ribbon Cable |
Signal Delay in Ribbon Cable
Experimental Set Up
| setup without Ribbon Cable | setup with Ribbon Cable |
Measurements
| 2 pulses without Ribbon Cable | 2 pulses with Ribbon Cable |
We have about 170 ns delay of signal in Ribbon Cable for 100 ns pulse. For other pulse width the delay is about the same.