Ribbon Cable Attenuation Measurements: Difference between revisions

From New IAC Wiki
Jump to navigation Jump to search
Shaproma (talk | contribs)
No edit summary
Shaproma (talk | contribs)
No edit summary
Line 1: Line 1:
[http://wiki.iac.isu.edu/index.php/PhotoFission_with_Polarized_Photons_from_HRRL Go Back]
[http://wiki.iac.isu.edu/index.php/PhotoFission_with_Polarized_Photons_from_HRRL Go Back]


=Experimental Set Up=
=Attenuation of Ribbon Cable measurements=
 
==Experimental Set Up==


{| border="1"  cellpadding="20" cellspacing="0"
{| border="1"  cellpadding="20" cellspacing="0"
Line 9: Line 11:
|}<br><br>
|}<br><br>


=Measurements=
==Measurements==


{| border="3"  cellpadding="20" cellspacing="0"
{| border="3"  cellpadding="20" cellspacing="0"
Line 28: Line 30:
  <math>V_2</math> - with Ribbon Cable
  <math>V_2</math> - with Ribbon Cable


=Pictures about change of pulse shape=
==Pictures about change of pulse shape==


{| border="1"  cellpadding="20" cellspacing="0"
{| border="1"  cellpadding="20" cellspacing="0"
Line 51: Line 53:
=Signal Delay in Ribbon Cable=
=Signal Delay in Ribbon Cable=


==Experimental Setup==
==Experimental Set Up==
 
{| border="1"  cellpadding="20" cellspacing="0"
| setup_2signal_without_Ribbon_Cable|| setup 2signal with Ribbon Cable
|-
| [[File:Setup before.JPG | 400 px]] || [[File:Setup after.JPG | 400 px]]
|}<br><br>


==Measurements==
==Measurements==

Revision as of 22:25, 19 January 2011

Go Back

Attenuation of Ribbon Cable measurements

Experimental Set Up

setup without Ribbon Cable setup with Ribbon Cable



Measurements

Pulse width [math]\displaystyle{ V_1 }[/math] [math]\displaystyle{ V_2 }[/math] Attenuation, % Comments
[math]\displaystyle{ 100\ \mu s }[/math] [math]\displaystyle{ 5.0\ V }[/math] [math]\displaystyle{ 4.5\ V }[/math] 10 %
[math]\displaystyle{ 10\ \mu s }[/math] [math]\displaystyle{ 5.0\ V }[/math] [math]\displaystyle{ 4.2\ V }[/math] 16 %
[math]\displaystyle{ 1\ \mu s }[/math] [math]\displaystyle{ 5.0\ V }[/math] [math]\displaystyle{ 3.0\ V }[/math] 40 % see pictures about change of pulse shape
[math]\displaystyle{ 100\ ns }[/math] [math]\displaystyle{ 5.0\ V }[/math] [math]\displaystyle{ 2.8\ V }[/math] 44 % see pictures about change of pulse shape
[math]\displaystyle{ 30\ ns }[/math] [math]\displaystyle{ 4.0\ V }[/math] [math]\displaystyle{ 1.8\ V }[/math] 55 % see pictures about change of pulse shape
[math]\displaystyle{ V_1 }[/math] - without Ribbon Cable
[math]\displaystyle{ V_2 }[/math] - with Ribbon Cable

Pictures about change of pulse shape

[math]\displaystyle{ 1\ \mu s }[/math] pulse without Ribbon Cable [math]\displaystyle{ 1\ \mu s }[/math] pulse with Ribbon Cable



[math]\displaystyle{ 100\ ns }[/math] pulse without Ribbon Cable [math]\displaystyle{ 100\ ns }[/math] pulse with Ribbon Cable



[math]\displaystyle{ 30\ ns }[/math] pulse without Ribbon Cable [math]\displaystyle{ 30\ ns }[/math] pulse with Ribbon Cable




Signal Delay in Ribbon Cable

Experimental Set Up

setup_2signal_without_Ribbon_Cable setup 2signal with Ribbon Cable



Measurements

2 pulses without Ribbon Cable 2 pulses with Ribbon Cable



We have about 170 ns delay of signal in Ribbon Cable for 100 ns pulse. 
For other pulse width the delay is about the same.


Go Back