Difference between revisions of "Lab 23 TF EIM"
Jump to navigation
Jump to search
(→I_{io}) |
|||
| Line 33: | Line 33: | ||
;<math>V_{out}= -\frac{R_1}{R_2} V_1 + \left ( 1 + \frac{R_1}{R_2}\right)V_{io} + R_2 I_{i}</math> | ;<math>V_{out}= -\frac{R_1}{R_2} V_1 + \left ( 1 + \frac{R_1}{R_2}\right)V_{io} + R_2 I_{i}</math> | ||
| − | Use the same technique and resistors | + | Use the same technique and resistors from the previous section to construct 2 equations and 2 unknowns and extract <math>I_{io}</math> |
[[Forest_Electronic_Instrumentation_and_Measurement]] | [[Forest_Electronic_Instrumentation_and_Measurement]] | ||
Revision as of 03:26, 3 November 2010
Inverting OP Amp
- Construct the inverting amplifier according to the wiring diagram below.
- insert a 0.1 F capacitor between ground and the OP power supply input pin.
Gain measurements
- Measure the gain as a function of frequency between 100 Hz and 2 MHz for three values of R_2 = 10 k, 100 k, 1M.
- Graph the above measurements with the Gain in units of decibels (dB) and with a logarithmic scale for the frequency axis.
Impedance
Input Impedance
- Measure for the 10 fold and 100 fold amplifier at ~100 Hz and 10 kHz frequency.
Output Impedance
- Measure for the 10 fold and 100 fold amplifier at ~100 Hz and 10 kHz frequency. Be sure to keep the output () undistorted
= and =}
Use the above equation and two measurements of , , and to extract and .
- measure for = 1 k, = 100 k, and=0 (grounded).
- measure [[File:V_{out}]] for = 10 k, = 1 M, and=0 (grounded).
- You can now construct 2 equations with 2 unknowns and .
Now we will put in a pull up resistor R_3 as shown below.
Instead of the current we have the current
Use the same technique and resistors from the previous section to construct 2 equations and 2 unknowns and extract