Difference between revisions of "Emittance/TWISS parameter extraction"

From New IAC Wiki
Jump to navigation Jump to search
Line 14: Line 14:
 
[[File:ISU_4.jpeg|200px|thumb|center|CEBAF graphical emittance tool with X data and results shown]]
 
[[File:ISU_4.jpeg|200px|thumb|center|CEBAF graphical emittance tool with X data and results shown]]
  
{| class="wikitable" style="text-align: center: width: 200px; height: 200px;"
+
{|
|+
+
|             || emittance|| beta ||alpha
 
|-
 
|-
|            | emittance| beta |alpha |
+
|            || (m-rad)  || (m)  ||       
|            | (m-rad)  | (m)  |      |
 
 
|-
 
|-
|X quad scan 1| 1.3e-6  | 0.35 | 2.0  |
+
|X quad scan 1 || 1.3e-6  || 0.35 || 2.0   
|Y quad scan 0| 3.7e-6  | 0.41 | 2.3  |
 
 
|-
 
|-
|+}
+
|Y quad scan 0 || 3.7e-6  || 0.41 || 2.3 
 +
|}

Revision as of 20:13, 22 October 2010

Using the perl/PDL script, beam sizes for Y (quad scan 0) and X (quad scan 1) were measured. These beam sizes were put into a "sdds" file so the nominal CEBAF emittance/TWISS tool could be used to plot and fit the data.

Two fits are performed a simple Least Squares Fit and one based on MINUIT. The LSF is also used to seed the MINUIT fit.

Y plot and the GUI with results for the first quad scan.

Y beam size squared vs K1*L
CEBAF graphical emittance tool with Y data and results shown



X plot and the GUI with results for the second quad scan.

X beam size squared vs K1*L
CEBAF graphical emittance tool with X data and results shown
emittance beta alpha
(m-rad) (m)
X quad scan 1 1.3e-6 0.35 2.0
Y quad scan 0 3.7e-6 0.41 2.3