Revision as of 20:13, 22 October 2010
Using the perl/PDL script, beam sizes for Y (quad scan 0) and X (quad scan 1) were measured. These beam sizes were put into a "sdds" file so the nominal CEBAF emittance/TWISS tool could be used to plot and fit the data.
Two fits are performed a simple Least Squares Fit and one based on MINUIT. The LSF is also used to seed the MINUIT fit.
Y plot and the GUI with results for the first quad scan.
X plot and the GUI with results for the second quad scan.
emittance | beta | alpha | |
(m-rad) | (m) | ||
X quad scan 1 | 1.3e-6 | 0.35 | 2.0 |
Y quad scan 0 | 3.7e-6 | 0.41 | 2.3 |