Difference between revisions of "Emittance/TWISS parameter extraction"

From New IAC Wiki
Jump to navigation Jump to search
Line 7: Line 7:
  
 
[[File:ISU_2.jpeg|200px|thumb|left|CEBAF graphical emittance tool with Y data and results shown]]
 
[[File:ISU_2.jpeg|200px|thumb|left|CEBAF graphical emittance tool with Y data and results shown]]
 +
 +
X plot and the GUI with results for the second quad scan.
 +
[[File:ISU_3.jpeg|200px|thumb|left|X beam size squared vs K1*L]]
 +
 +
[[File:ISU_4.jpeg|200px|thumb|left|CEBAF graphical emittance tool with X data and results shown]]

Revision as of 20:01, 22 October 2010

Using the perl/PDL script, beam sizes for Y (quad scan 0) and X (quad scan 1) were measured. These beam sizes were put into a "sdds" file so the nominal CEBAF emittance/TWISS tool could be used to plot and fit the data.

Two fits are performed a simple Least Squares Fit and one based on MINUIT. The LSF is also used to seed the MINUIT fit.

Y plot and the GUI with results for the first quad scan.

Y beam size squared vs K1*L
CEBAF graphical emittance tool with Y data and results shown

X plot and the GUI with results for the second quad scan.

X beam size squared vs K1*L
CEBAF graphical emittance tool with X data and results shown