Minimum accelerator energy to run experiment

Min energy.png

The minimum energy of accelerator (MeV) is limited by fitting the collimator (r2) into the hole (R=8.73 cm)

[math]x_2 + r_2 = R[/math]

1) Assuming the collimator diameter is ΘC:

[math]\frac{1}{\sqrt{2}}\ (286+183)\ \tan\left(\frac{0.511}{E_{min}}\right) +
       \frac{1}{2}\ (286+183)\ \tan\left(\frac{0.511}{E_{min}}\right) = 8.73 \Rightarrow E_{min} = 33.1\ MeV  [/math]

2) Assuming the collimator diameter is ΘC/2:

[math]\frac{1}{\sqrt{2}}\ (286+183)\ \tan\left(\frac{0.511}{E_{min}}\right) +
       \frac{1}{2}\ (286+183)\ \tan\left(\frac{1}{2}\ \frac{0.511}{E_{min}}\right) = 8.73 \Rightarrow E_{min} = 26.3\ MeV  [/math]

3) Assuming the collimator diameter is ΘC/4:

[math]\frac{1}{\sqrt{2}}\ (286+183)\ \tan\left(\frac{0.511}{E_{min}}\right) +
       \frac{1}{2}\ (286+183)\ \tan\left(\frac{1}{4}\ \frac{0.511}{E_{min}}\right) = 8.73 \Rightarrow E_{min} = 22.8\ MeV  [/math]

4) In general:

Plot energy collimatorsize.jpeg

25 MeV geometry

geometry calculation

collimator diameter Θcritical Θkicker αcollimator AC A1C1 BD B1D1 FA F1F
Θcritical2 1.17o 0.83o 2.03o 4.13 cm 6.78 cm 2.92 cm 4.79 cm 75 cm 143 cm
Θcritical4 1.17o 0.83o 1.43o 4.13 cm 6.78 cm 1.46 cm 2.40 cm 136 cm 203 cm

geometry pictures

how it looks 1 (Θc/2, box 3"x4" and then pipe 4")

File:Vacuum pipe collimator .png

how it looks 2 (Θc/4, box 3"x4" and then pipe 4")

File:Vacuum pipe collimator .png


Go Back