− | ==Critical angle== | + | ==Critical and kicker angle== |
− | <math>\ | + | <math>\Theta_{critical} = \frac{m_ec^2}{E_{beam}} = \frac{0.511\ MeV}{44\ MeV} = 0.67\ ^o</math><br> |
+ | <math>\Theta_{kicker} = \frac{1}{\sqrt{2}}\frac{m_ec^2}{E_{beam}} = \frac{0.511\ MeV}{44\ MeV} = 0.67\ ^o</math><br> | ||
==Kicker angle and displacements on the wall== | ==Kicker angle and displacements on the wall== |