Difference between revisions of "Geometry (44 MeV LINAC exit port)"
Jump to navigation
Jump to search
Line 65: | Line 65: | ||
<math> FA = \frac{AB}{\tan (1.16^o)} = \frac{1.52\ cm}{\tan (1.16^o)} = 75\ cm </math> | <math> FA = \frac{AB}{\tan (1.16^o)} = \frac{1.52\ cm}{\tan (1.16^o)} = 75\ cm </math> | ||
− | ==how it looks== | + | ==how it looks (<math> \Theta_c/2</math>)== |
[[File:vacuum_pipe_collimator_0.335_1.png]]<br> | [[File:vacuum_pipe_collimator_0.335_1.png]]<br> |
Revision as of 20:41, 25 May 2010
Some measurements of 90 experimental degree exit port
Critical angle and displacement calculations
Kicker angle and displacement calculations
1 foot = 30.48 cm
accelerator's side wall
detector's side wall
Off-axis collimation geometry
Vacuum pipe location ( )
collimator location
1) center position:
(wall 1)
(wall 2)
2) collimator diameter:
(wall 1)
(wall 2)
collimator critical angle
from triangle
:
minimal distance from the wall
from triangle FAB:
how it looks ( )
Vacuum pipe location ( )
collimator location
1) center position:
(wall 1)
(wall 2)
2) collimator diameter:
(wall 1)
(wall 2)
collimator critical angle
from triangle
:
minimal distance from the wall
from triangle FAB: