Line 65: | Line 65: | ||
<math> FA = \frac{AB}{\tan (1.16^o)} = \frac{1.52\ cm}{\tan (1.16^o)} = 75\ cm </math> | <math> FA = \frac{AB}{\tan (1.16^o)} = \frac{1.52\ cm}{\tan (1.16^o)} = 75\ cm </math> | ||
− | == | + | ==how it looks== |
[[File:vacuum_pipe_collimator_0.335.png]]<br> | [[File:vacuum_pipe_collimator_0.335.png]]<br> | ||
− | |||
=Vacuum pipe location (<math> \Theta_c/4</math>)= | =Vacuum pipe location (<math> \Theta_c/4</math>)= |
Revision as of 18:50, 25 May 2010
Some measurements of 90 experimental degree exit port
Critical angle and displacement calculations
Kicker angle and displacement calculations
1 foot = 30.48 cm
accelerator's side wall
detector's side wall
Off-axis collimation geometry
Vacuum pipe location ( )
collimator location
1) center position:
(wall 1)
(wall 2)
2) collimator diameter:
(wall 1)
(wall 2)
collimator critical angle
from triangle
:
minimal distance from the wall
from triangle FAB:
how it looks
Vacuum pipe location ( )
collimator location
1) center position:
(wall 1)
(wall 2)
2) collimator diameter:
(wall 1)
(wall 2)
collimator critical angle
from triangle
:
minimal distance from the wall
from triangle FAB: