Difference between revisions of "Qweak GEM installation log book"

From New IAC Wiki
Jump to navigation Jump to search
Line 17: Line 17:
 
[[File:GASbottleoutsidetheDoghouse-12-05-2010.jpg|300px]][[File:GEMShieldedRibbonCables-12-05-2010.jpg|300px]]
 
[[File:GASbottleoutsidetheDoghouse-12-05-2010.jpg|300px]][[File:GEMShieldedRibbonCables-12-05-2010.jpg|300px]]
  
=13-05-2010=
+
=5/13/2010=
  
 
Gumstix and I2C
 
Gumstix and I2C

Revision as of 17:35, 13 May 2010

5/12/2010

Detector installation

The Qweak GEM detector has been installed in the doghouce in Hall-C and the HV was turned on. On the scope picture below is shown the GEM trigger out pulse, after it has been amplified and integrated with timing filter amplifier. The high voltage supply is placed in the doghouse with the other electronics.

GEMTrigOutinDoghouse-12-05-2010.jpgGEMTrigOutandGEMdetectorinDoghouse-12-05-2010.jpg

GEMSetUPinDoghouse-12-05-2010.jpg

Electronics

We have the NIM Bin with the following modules: Leading edge discriminator, timing filter amplifier(X2), Gumstix module.
GEMNIMBINandModulese-12-05-2010.jpgGEMGumstixandI2CNIMModuleinDoghouse-12-05-2010.jpg

Gas

The gas bottle filled with ArCO2 is placed outside the doghouse. We have two 90 ft shielded twisted ribbon cables next to region 1 area. GASbottleoutsidetheDoghouse-12-05-2010.jpgGEMShieldedRibbonCables-12-05-2010.jpg

5/13/2010

Gumstix and I2C