Difference between revisions of "Syed LCS G4ModelPaper"
(2 intermediate revisions by the same user not shown) | |||
Line 35: | Line 35: | ||
==Apparatus== | ==Apparatus== | ||
− | Insert diagram of electron accelerator and laser (boxes) and electron - photon symbols. Then next to it put a Lab Frame coordinate system with variables. Then a CM frame coordinate system with variables | + | Insert diagram of electron accelerator and laser (boxes) and electron - photon symbols. |
+ | Then next to it put a Lab Frame coordinate system with variables. | ||
+ | Then a CM frame coordinate system with variables | ||
==Physics Model== | ==Physics Model== | ||
Line 66: | Line 68: | ||
BNL- | BNL- | ||
+ | |||
+ | 4.) Compton polarization G4 model | ||
+ | http://www-zeuthen.desy.de/~dreas/geant4/ | ||
Acknowledgements. The authors gratefully acknowledge the support of this project from the Department of Defense (DOD) under contract, DOD#FA8650-04-2-6541. | Acknowledgements. The authors gratefully acknowledge the support of this project from the Department of Defense (DOD) under contract, DOD#FA8650-04-2-6541. |
Latest revision as of 15:28, 1 May 2009
LCS in G4
describe below the performance of the Compton scattering models in G4 and motivate reference frame boost approach.
Abstract
Describe Simulation (write last)
Introduction
Tunable and quasi-monochromatic laser Compton scattered (LCS) X-rays are produced as a result of the interaction between accelerated electrons and a laser beam. The energy tunability of LCS X-rays is dependent on the incoming electron and laser beam energies.
quantify SNR improvement
The quasi-monochromatic nature of LCS X-rays improve the performance of radiography applications due to the higher signal-to-noise ratio compared to conventional X-ray tubes.
quantify significantly
Significantly lower X-ray doses per image both to the object/patient and workers are possible.
Previously, two 20.94 keV and 98.4 keV LCS peaks, having a FWHM = ???, were produced at the Idaho Accelerator Center (IAC) in two separate experiments using electron beam energies of ~34 MeV and ~37 MeV respectively that intersected a 4 GigaWatt peak power Nd:YAG laser operating at wavelengths of 1064 nm and 266 nm. The electron linear accelerator (linac) was operating at 60 Hz with an electron beam pulse length of 50 ps and a peak current of 7 Amps. A simulation has been performed using a Geant4 Monte Carlo simulation toolkit to further understand features of the experimental yield, such as the influence of the energy distribution of the incoming electron beam. A comparison between simulated and experimental LCS X-rays of ~20 keV and ~98 keV as well as radiographic images of fish and lead samples will be shown.
Theory
Start with Klein-Nishina paper then go to Stepanek paper. Paraphrase contents, use your own words, include necessary formula
The differential cross section describing the Compton scattering of a photon by an electron at rest is given by the Klein-Nishina formula ~\cite{KleinNishina1929} as:
where
is the bohr radius, is the electron photon scattering angle andApparatus
Insert diagram of electron accelerator and laser (boxes) and electron - photon symbols. Then next to it put a Lab Frame coordinate system with variables. Then a CM frame coordinate system with variables
Physics Model
Compton scattering equation
insert compton scattering information with references on how it is implemented in GEANT4
Transformation to electron rest frame
Comparison with Experiment
Compton Energy Distribution
Rates
References
\cite{KleinNishina1929} Oskar Klein & Yoshio Nashina, Z. Phys., vol 52 (1929), pg 853 )
2.) GEANT4
3.) Reference for GEANT4 Compton scattering Model
Stepanek NIMA 412 1998pg174.pdf say
BNL-47503
BNL-
4.) Compton polarization G4 model
http://www-zeuthen.desy.de/~dreas/geant4/
Acknowledgements. The authors gratefully acknowledge the support of this project from the Department of Defense (DOD) under contract, DOD#FA8650-04-2-6541.