Difference between revisions of "October 16, 2008"
Jump to navigation
Jump to search
(10 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
NaI detector in place and working (used to measure the gamma flash). | NaI detector in place and working (used to measure the gamma flash). | ||
− | |||
− | |||
Asymmetry was observed for <math>D_{2}O</math>: | Asymmetry was observed for <math>D_{2}O</math>: | ||
Line 12: | Line 10: | ||
<math>A^{n,D_{2}O}_{side}</math> is the number of neutrons/sec seen by the detector when placed to the side of the <math> D_{2}O </math> target. | <math>A^{n,D_{2}O}_{side}</math> is the number of neutrons/sec seen by the detector when placed to the side of the <math> D_{2}O </math> target. | ||
− | Detector A Asymmetry: First run = 20.27%; Second run = 19.84% | + | <math>A^{n,H_{2}O}_{up}</math> is the number of neutrons/sec seen by the detector when placed above the <math> H_{2}O </math> target. |
+ | |||
+ | <math>A^{n,H_{2}O}_{side}</math> is the number of neutrons/sec seen by the detector when placed to the side of the <math> H_{2}O </math> target. | ||
+ | |||
+ | <math>N^{ref,D_{2}O}_{r}</math> is the number of neutrons/sec seen by the reference detector with the <math> D_{2}O </math> target. (The reference detector is beside the place of the side detector.) | ||
+ | |||
+ | <math>N^{ref,H_{2}O}_{r}</math> is the number of neutrons/sec seen by the reference detector with the <math> H_{2}O </math> target. (The reference detector is beside the place of the side detector.) | ||
+ | |||
+ | Detector A Asymmetry: First run = -20.27%; Second run = -19.84% | ||
+ | |||
+ | Detector C Asymmetry: First run = -12.69%; Second run = -9.16% | ||
+ | |||
+ | [[Image:Four_detectors_asymmetry.jpg | 500 px]] | ||
− | + | On the picture: 1D - timing spectrum taken by upper detector, 1C - timing spectrum taken by side detector, 1A - timing spectrum taken by side reference (being kept stationary) detector, 1B - NaI accelerator current monitor | |
− | [http:// | + | [http://wiki.iac.isu.edu/index.php/October_Fission_HRRL_Measurements_2008 Go Back] |
Latest revision as of 06:31, 5 February 2009
NaI detector in place and working (used to measure the gamma flash).
Asymmetry was observed for
:
is the number of neutrons/sec seen by the detector when placed above the target.
is the number of neutrons/sec seen by the detector when placed to the side of the target.
is the number of neutrons/sec seen by the detector when placed above the target.
is the number of neutrons/sec seen by the detector when placed to the side of the target.
is the number of neutrons/sec seen by the reference detector with the target. (The reference detector is beside the place of the side detector.)
is the number of neutrons/sec seen by the reference detector with the target. (The reference detector is beside the place of the side detector.)
Detector A Asymmetry: First run = -20.27%; Second run = -19.84%
Detector C Asymmetry: First run = -12.69%; Second run = -9.16%
On the picture: 1D - timing spectrum taken by upper detector, 1C - timing spectrum taken by side detector, 1A - timing spectrum taken by side reference (being kept stationary) detector, 1B - NaI accelerator current monitor