Line 39: | Line 39: | ||
| Parameter || Dial setting | | Parameter || Dial setting | ||
|- | |- | ||
− | | Timing Amp1 || | + | | Timing Amp1 || x20 |
|- | |- | ||
| Timing Amp1 Integration || 50 ns | | Timing Amp1 Integration || 50 ns | ||
|- | |- | ||
− | | Timing Amp2 || | + | | Timing Amp2 || x4 |
|- | |- | ||
| Timing Amp2 Integration || 20 ns | | Timing Amp2 Integration || 20 ns |
Revision as of 23:33, 10 October 2008
TGEMS : defined as GEM detector which use thick PCboard (0.4 mm thick) size GEM preamplifiers with hole diameters between 0.5 and 1 mm.
PCboard spacing = 1.5 - 2 mm.
TGEM Detector HV setting
[2]Media:Development_of_Tracking_Detectors_with_industrially_produced_GEM_Foils.pdf
Descriminated signals
HV setting
Cathode HV (Volts) | First THGEM foil(Volts) | Second THGEM foil(Volts) | Third THGEM foil(Volts) | Third THGEM foil current | A
3000 | 1756 | 1657 | 1652 | 1273 |
Descriminator setup
I used 2 timing amps to integrate the signal and amplify more then the basic GEM.
The following setttings were
Parameter | Dial setting |
Timing Amp1 | x20 |
Timing Amp1 Integration | 50 ns |
Timing Amp2 | x4 |
Timing Amp2 Integration | 20 ns |
CFD Threshold | 5.22 |
CFD Threshold ULD | 5.28 |
CFD Threshold LLD | 3.04 |