Difference between revisions of "TGEMS"
Jump to navigation
Jump to search
Line 23: | Line 23: | ||
== HV setting== | == HV setting== | ||
+ | | border="1" |cellpadding="20" cellspacing="0 | ||
+ | | Cathode HV (Volts) || First THGEM foil(Volts) || Second THGEM foil(Volts) || Third THGEM foil(Volts) || Third THGEM foil current <math>\mu</math>A | ||
+ | |- | ||
+ | | 3000 || 1756 || 1657 || 1652 || 1273 | ||
+ | |}<br> | ||
== Descriminator setup== | == Descriminator setup== |
Revision as of 22:37, 10 October 2008
TGEMS : defined as GEM detector which use thick PCboard (0.4 mm thick) size GEM preamplifiers with hole diameters between 0.5 and 1 mm.
PCboard spacing = 1.5 - 2 mm.
TGEM Detector HV setting
[2]Media:Development_of_Tracking_Detectors_with_industrially_produced_GEM_Foils.pdf
Descriminated signals
HV setting
| border="1" |cellpadding="20" cellspacing="0
| Cathode HV (Volts) || First THGEM foil(Volts) || Second THGEM foil(Volts) || Third THGEM foil(Volts) || Third THGEM foil current