Difference between revisions of "Matching Detectors"
Jump to navigation
Jump to search
(8 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
+ | [http://wiki.iac.isu.edu/index.php/PhotoFission_with_Polarized_Photons_from_HRRL Go Back] | ||
+ | |||
+ | |||
=Detector C= | =Detector C= | ||
Line 141: | Line 144: | ||
== Rate VS Threshold (Detecotr C)== | == Rate VS Threshold (Detecotr C)== | ||
+ | === HV at 1560V=== | ||
+ | |||
+ | {| border="1" cellpadding="20" cellspacing="0" | ||
+ | |||
+ | |||
+ | |- | ||
+ | |Threshold (mV) | ||
+ | |Counts/5min | ||
+ | |- | ||
+ | | 20||6625 | ||
+ | |- | ||
+ | | 40|| 2882 | ||
+ | |- | ||
+ | | 60|| 1299 | ||
+ | |- | ||
+ | | 80|| 785 | ||
+ | |- | ||
+ | | 100||579 | ||
+ | |- | ||
+ | | 120||399 | ||
+ | |- | ||
+ | | 140 ||390 | ||
+ | |- | ||
+ | | 160||349 | ||
+ | |- | ||
+ | | 180|| 372 | ||
+ | |- | ||
+ | |200||347 | ||
+ | |- | ||
+ | | 220||301 | ||
+ | |- | ||
+ | | 240 ||312 | ||
+ | |- | ||
+ | | 255||307 | ||
+ | |} | ||
=Detector B= | =Detector B= | ||
Line 246: | Line 284: | ||
|Counts/5min | |Counts/5min | ||
|- | |- | ||
− | | || | + | | 20||3500 |
+ | |- | ||
+ | | 40|| 1016 | ||
+ | |- | ||
+ | | 60|| 523 | ||
+ | |- | ||
+ | | 80|| 351 | ||
+ | |- | ||
+ | | 100||325 | ||
+ | |- | ||
+ | | 120||318 | ||
+ | |- | ||
+ | | 140||281 | ||
+ | |- | ||
+ | | 160||257 | ||
+ | |- | ||
+ | | 180|| 271 | ||
+ | |- | ||
+ | | 200||248 | ||
+ | |- | ||
+ | | 220||249 | ||
+ | |- | ||
+ | | 240||223 | ||
+ | |- | ||
+ | | 255||241 | ||
+ | |} | ||
+ | |||
+ | =Detector A= | ||
+ | |||
+ | Crystal of Detector A is Polished, its PMT is the same PMT used on detector B. | ||
+ | |||
+ | |||
+ | == Rate VS HV (Detecotr A)== | ||
+ | |||
+ | |||
+ | ===Threshold at 220 mV (Detecotr A)=== | ||
+ | |||
+ | {| border="1" cellpadding="20" cellspacing="0" | ||
+ | |||
+ | |||
+ | |- | ||
+ | |High Voltage (Volts) | ||
+ | |Counts/5min | ||
+ | |- | ||
+ | |1500 || 166 | ||
+ | |- | ||
+ | |1550|| 233 | ||
+ | |- | ||
+ | |1600 || 266 | ||
+ | |- | ||
+ | |1650 || 306 | ||
+ | |- | ||
+ | |1700|| 305 | ||
+ | |- | ||
+ | |1750|| 364 | ||
+ | |- | ||
+ | |1800 || 564 | ||
+ | |- | ||
+ | |1850 || 870 | ||
+ | |- | ||
+ | |1900|| 1900 | ||
+ | |} | ||
+ | |||
+ | |||
+ | == Rate VS Threshold (Detecotr A)== | ||
+ | |||
+ | === HV at 1560V=== | ||
+ | |||
+ | {| border="1" cellpadding="20" cellspacing="0" | ||
+ | |||
+ | |||
+ | |- | ||
+ | |Threshold (mV) | ||
+ | |Counts/5min | ||
+ | |- | ||
+ | | 20||2983 | ||
+ | |- | ||
+ | | 40|| 881 | ||
+ | |- | ||
+ | | 60|| 452 | ||
+ | |- | ||
+ | | 80|| 345 | ||
+ | |- | ||
+ | | 100||337 | ||
+ | |- | ||
+ | | 110||315 | ||
+ | |- | ||
+ | | 120||296 | ||
+ | |- | ||
+ | | 140||303 | ||
|- | |- | ||
− | | || | + | | 160||267 |
|- | |- | ||
− | | || | + | | 180||246 |
|- | |- | ||
− | | || | + | | 200||218 |
|- | |- | ||
− | | || | + | |220 ||227 |
|- | |- | ||
− | | || | + | |240 ||208 |
|- | |- | ||
− | | || | + | | 255||192 |
|- | |- | ||
| || | | || | ||
|} | |} | ||
+ | |||
+ | [http://wiki.iac.isu.edu/index.php/PhotoFission_with_Polarized_Photons_from_HRRL Go Back] |
Latest revision as of 06:23, 5 February 2009
Detector C
Rate VS HV (Detecotr C)
Threshold at 80 mV (Detecotr C)
High Voltage (Volts) | Counts/5min |
1500 | 563 |
1550 | 949 |
1600 | 1912 |
1650 | 3191 |
1700 | 4557 |
1750 | 6235 |
1800 | 7900 |
1850 | 9789 |
1900 | 12192 |
High Voltage (Volts) | Counts/1min |
2000 | 4444 |
2100 | 14739 |
Threshold at 150 mV (Detecotr C)
High Voltage (Volts) | Counts/5min |
1500 | 173 |
1550 | 226 |
1600 | 284 |
1650 | 313 |
1700 | 375 |
1750 | 449 |
1800 | 685 |
High Voltage (Volts) | Counts/1min |
1850 | 213 |
1900 | 382 |
2000 | 782 |
2100 | 1311 |
Threshold at 170 mV (Detecotr C)
High Voltage (Volts) | Counts/5min |
1500 | 282 |
1550 | 310 |
1600 | 380 |
1650 | 463 |
1700 | 743 |
1750 | 1274 |
1800 | 2166 |
Threshold at 220 mV (Detecotr C)
High Voltage (Volts) | Counts/5min |
1500 | 302 |
1550 | 347 |
1600 | 387 |
1650 | 594 |
1700 | 392 |
1800 | 2889 |
Rate VS Threshold (Detecotr C)
HV at 1560V
Threshold (mV) | Counts/5min |
20 | 6625 |
40 | 2882 |
60 | 1299 |
80 | 785 |
100 | 579 |
120 | 399 |
140 | 390 |
160 | 349 |
180 | 372 |
200 | 347 |
220 | 301 |
240 | 312 |
255 | 307 |
Detector B
Rate VS HV (Detecotr B)
Threshold at 80 mV (Detecotr B)
High Voltage (Volts) | Counts/5min |
1500 | 290 |
1550 | 316 |
1600 | 350 |
1650 | 470 |
1750 | 1267 |
High Voltage (Volts) | Counts/1min |
1850 | 671 |
1950 | 1197 |
2050 | 1678 |
Threshold at 170 mV (Detecotr B)
High Voltage (Volts) | Counts/5min |
1500 | 148 |
1550 | 236 |
1600 | 241 |
1650 | 281 |
1700 | 231 |
1750 | 586 |
1800 | 1388 |
Threshold at 220 mV (Detecotr B)
High Voltage (Volts) | Counts/5min |
1500 | 190 |
1550 | 205 |
1600 | 276 |
1650 | 290 |
1700 | 343 |
1750 | 436 |
1800 | 615 |
1900 | 1715 |
Rate VS Threshold (Detecotr B)
HV at 1560V
Threshold (mV) | Counts/5min |
20 | 3500 |
40 | 1016 |
60 | 523 |
80 | 351 |
100 | 325 |
120 | 318 |
140 | 281 |
160 | 257 |
180 | 271 |
200 | 248 |
220 | 249 |
240 | 223 |
255 | 241 |
Detector A
Crystal of Detector A is Polished, its PMT is the same PMT used on detector B.
Rate VS HV (Detecotr A)
Threshold at 220 mV (Detecotr A)
High Voltage (Volts) | Counts/5min |
1500 | 166 |
1550 | 233 |
1600 | 266 |
1650 | 306 |
1700 | 305 |
1750 | 364 |
1800 | 564 |
1850 | 870 |
1900 | 1900 |
Rate VS Threshold (Detecotr A)
HV at 1560V
Threshold (mV) | Counts/5min |
20 | 2983 |
40 | 881 |
60 | 452 |
80 | 345 |
100 | 337 |
110 | 315 |
120 | 296 |
140 | 303 |
160 | 267 |
180 | 246 |
200 | 218 |
220 | 227 |
240 | 208 |
255 | 192 |