Difference between revisions of "CHIPS IAC Run 5-28-08"
Jump to navigation
Jump to search
Line 43: | Line 43: | ||
|- | |- | ||
|SOL2 || 8.59 | |SOL2 || 8.59 | ||
+ | |} | ||
+ | |||
+ | =MPA RUns= | ||
+ | |||
+ | {| border="1" |cellpadding="20" cellspacing="0 | ||
+ | |- | ||
+ | |Run # || MPA file name || Description | ||
+ | |- | ||
+ | |6|| NaI006.mpa || Background measurement, no source | ||
+ | |- | ||
+ | |7|| NaI007.mpa || Na-22 source on top of NaI detector | ||
+ | |- | ||
+ | |8| NaI008.mpa || change spec amp gain from 500 to 200 | ||
+ | |- | ||
+ | |9| NaI009.mpa || Co-60 source on top of NaI, Na-22 removed, Spec amp gain back to 500 | ||
+ | |- | ||
+ | |10| NaI010.mpa || change spec amp gain from 500 to 1000, put Na-22 and Co-60 on top of Nai | ||
|} | |} | ||
[http://www.iac.isu.edu/mediawiki/index.php/CHIPS_Run_May-2008 Go Back] | [http://www.iac.isu.edu/mediawiki/index.php/CHIPS_Run_May-2008 Go Back] |
Revision as of 13:18, 28 May 2008
Delay from gun is about 400 ns gate width between 400 and 800 ns
Tune 4 MeV electrons into Experimental Cell
Optics elements 45Q2, Bend2, L90Q1m L90Q2 are after the tungsten converter.
Device | setting |
RS1 | -0.46 |
RS2 | +0.77 |
FS1 | -0.68 |
FS2 | 0.00 |
0Q1 | +0.76 |
0Q2 | +0.94 |
45Q1 | +0.02 |
45Q2 | +1.37 |
L90Q1 | -2.98 |
L90Q2 | +0.98 |
Bend1 | +1.42 |
Bend2 | +10.66 |
Gun HV | 20 kV |
Grid | 4.84 |
802 | 13.2 kV |
SOL1 | 0.00 |
SOL2 | 8.59 |
MPA RUns
Run # | MPA file name | Description |
6 | NaI006.mpa | Background measurement, no source |
7 | NaI007.mpa | Na-22 source on top of NaI detector |
NaI008.mpa | change spec amp gain from 500 to 200 | |
NaI009.mpa | Co-60 source on top of NaI, Na-22 removed, Spec amp gain back to 500 | |
NaI010.mpa | change spec amp gain from 500 to 1000, put Na-22 and Co-60 on top of Nai |