Difference between revisions of "MiniDC Signals 4-25-08"

From New IAC Wiki
Jump to navigation Jump to search
 
(15 intermediate revisions by the same user not shown)
Line 1: Line 1:
High voltage on sense wires and on PreAmp is turned off. The PreAmp cables are connected to the DC(Metalica and Plastika).(ground on sense wire 4(M&P))
+
=The PreAmp Power supply connected to The DC=
 +
 
 +
Ground wire '''on''' of Metalica and Plastika. DC High voltage off, PreAmp HV off. The PreAmp Power supply connected to the DC(Metalica and Plastika).
 
<br>
 
<br>
  
Line 5: Line 7:
  
  
High voltage on sense wires and on PreAmp is turned off. The PreAmp cables are connected to the DC(Metalica and Plastika).(ground on sense wire 4(Plastika))
+
Ground wire '''Off''' of Metalic. Ground wire '''On''' Plastika. DC High voltage off, Preamp HV off. The PreAmp Power supply connected to the DC(Metalica and Plastika).
 
<br>
 
<br>
  
Line 12: Line 14:
  
  
 
+
Ground wire '''on''' of Metalica. Ground wire '''of''' Plastika. DC High voltage off, PreAmp HV off. The PreAmp Power supply connected to the DC(Metalica and Plastika)
High voltage on sense wires and on PreAmp is turned off. The PreAmp cables are connected to the DC(Metalica and Plastika).(ground on sense wire 4(Metalica))
 
 
<br>
 
<br>
  
 
[[Image:noise_level_on_plastika_and_metalica_PreAmp_off_cables_connected_HV_off_ground_on_sense_wire_4_M.png|300px]]<br>
 
[[Image:noise_level_on_plastika_and_metalica_PreAmp_off_cables_connected_HV_off_ground_on_sense_wire_4_M.png|300px]]<br>
 +
 +
 +
Ground wire '''of''' of Metalica. Ground wire '''of''' Plastika. DC High voltage off, PreAmp HV off. The PreAmp Power supply connected to the DC(Metalica and Plastika)
 +
 +
 +
[[Image:noise_level_on_plastika_and_metalica_PreAmp_off_cables_connected_HV_off.png|300px]]<br>
 +
 +
=The PreAmp Power supply unplugged=
 +
 +
 +
Ground wire '''on''' of Metalica and Plastika. DC High voltage off.<br>
 +
 +
[[Image:noise_level_on_plastika_and_metalica_HV_off_ground_on_sense_wire_4.png|300px]]<br>
 +
 +
 +
 +
 +
Ground wire '''of''' of Metalica and Plastika. DC High voltage off.<br>
 +
 +
[[Image:noise_level_on_plastika_and_metalica_HV_off_ground.png|300px]]<br>
 +
 +
 +
 +
Ground wire '''on''' of Metalica. Ground wire '''off''' of Plastika. DC High voltage off.<br>
 +
 +
[[Image:noise_level_on_plastika_and_metalica_HV_off_ground_on_sense_wire_4_m.png|300px]]<br>
 +
 +
 +
 +
Ground wire '''off''' of Metalica. Ground wire '''on''' of Plastika. DC High voltage off.<br>
 +
 +
 +
[[Image:noise_level_on_plastika_and_metalica_HV_off_ground_on_sense_wire_4_p.png|300px]]<br>
 +
 +
=The DC HV on=
 +
 +
Ground wire '''on''' of Metalica and Plastika. The DC HV '''on'''. The PreAmp Power supply unplugged from The DC.<br>
 +
 +
==Sense Wire4 HV=1450V==
 +
 +
[[Image:noise_level_on_sense_wire_4_of_Plastika_and_Metalica_HV_on_1450V.png|300px]]
 +
 +
==Sense Wire4 HV=1500V==
 +
 +
[[Image:noise_level_on_sense_wire_4_of_Plastika_and_Metalica_HV_on_1500V.png|300px]]
 +
 +
==Sense Wire4 HV=1550V==
 +
 +
[[Image:noise_level_on_sense_wire_4_of_Plastika_and_Metalica_HV_on_1550V.png|300px]]
  
  
 
[http://www.iac.isu.edu/mediawiki/index.php/Mini-prototype G0 Back]
 
[http://www.iac.isu.edu/mediawiki/index.php/Mini-prototype G0 Back]

Latest revision as of 20:33, 25 April 2008

The PreAmp Power supply connected to The DC

Ground wire on of Metalica and Plastika. DC High voltage off, PreAmp HV off. The PreAmp Power supply connected to the DC(Metalica and Plastika).

Noise level on plastika and metalica PreAmp off cables connected HV off ground on sense wire 4.png


Ground wire Off of Metalic. Ground wire On Plastika. DC High voltage off, Preamp HV off. The PreAmp Power supply connected to the DC(Metalica and Plastika).

Noise level on plastika and metalica PreAmp off cables connected HV off ground on sense wire 4 P.png


Ground wire on of Metalica. Ground wire of Plastika. DC High voltage off, PreAmp HV off. The PreAmp Power supply connected to the DC(Metalica and Plastika)

Noise level on plastika and metalica PreAmp off cables connected HV off ground on sense wire 4 M.png


Ground wire of of Metalica. Ground wire of Plastika. DC High voltage off, PreAmp HV off. The PreAmp Power supply connected to the DC(Metalica and Plastika)


Noise level on plastika and metalica PreAmp off cables connected HV off.png

The PreAmp Power supply unplugged

Ground wire on of Metalica and Plastika. DC High voltage off.

Noise level on plastika and metalica HV off ground on sense wire 4.png



Ground wire of of Metalica and Plastika. DC High voltage off.

Noise level on plastika and metalica HV off ground.png


Ground wire on of Metalica. Ground wire off of Plastika. DC High voltage off.

Noise level on plastika and metalica HV off ground on sense wire 4 m.png


Ground wire off of Metalica. Ground wire on of Plastika. DC High voltage off.


Noise level on plastika and metalica HV off ground on sense wire 4 p.png

The DC HV on

Ground wire on of Metalica and Plastika. The DC HV on. The PreAmp Power supply unplugged from The DC.

Sense Wire4 HV=1450V

Noise level on sense wire 4 of Plastika and Metalica HV on 1450V.png

Sense Wire4 HV=1500V

Noise level on sense wire 4 of Plastika and Metalica HV on 1500V.png

Sense Wire4 HV=1550V

Noise level on sense wire 4 of Plastika and Metalica HV on 1550V.png


G0 Back