PreAmp is turned off.<br> | PreAmp is turned off.<br> | ||
+ | The left picture has Platika on Ch 1 the right picture swaps the cables between the scope and the sense wire. Hence, Metalica is shown on Ch1 after swapping the leads. | ||
{| border="1" |cellpadding="20" cellspacing="0 | {| border="1" |cellpadding="20" cellspacing="0 | ||
|colspan= "3" | HV settings | |colspan= "3" | HV settings | ||
Line 13: | Line 14: | ||
|} | |} | ||
Noise: | Noise: | ||
− | [[Image:BabyChamber_Noise_Wire4_HV_on_1500V_4-22-08.png | | + | [[Image:BabyChamber_Noise_Wire4_HV_on_1500V_4-22-08.png | 200 px]][[Image:BabyChamber_NoiseWire4_HV_on_1500V_4-22-08_1.png | 200 px]]<br> |
− | + | ||
− | |||
{| border="1" |cellpadding="20" cellspacing="0 | {| border="1" |cellpadding="20" cellspacing="0 | ||
Line 29: | Line 29: | ||
|} | |} | ||
Noise: | Noise: | ||
− | [[Image:BabyChamber_Noise_Wire4_HV_on_1550V_4-22-08.png | | + | [[Image:BabyChamber_Noise_Wire4_HV_on_1550V_4-22-08.png | 200 px]][[Image:BabyChamber_Noise_Wire4_HV_on_1550V_4-22-08_1.png | 200 px]]<br> |
− | |||
− | |||
{| border="1" |cellpadding="20" cellspacing="0 | {| border="1" |cellpadding="20" cellspacing="0 | ||
Line 45: | Line 43: | ||
|} | |} | ||
Noise: | Noise: | ||
− | [[Image:BabyChamber_Noise_Wire4_HV_on_1450V_4-22-08.png | | + | [[Image:BabyChamber_Noise_Wire4_HV_on_1450V_4-22-08.png | 200 px]][[Image:BabyChamber_Noise_Wire4_HV_on_1450V_4-22-08_1.png | 200 px]]<br> |
− | |||
− | |||
[http://www.iac.isu.edu/mediawiki/index.php/Mini-prototype G0 Back] | [http://www.iac.isu.edu/mediawiki/index.php/Mini-prototype G0 Back] |
Latest revision as of 17:33, 24 April 2008
PreAmp is turned off.
The left picture has Platika on Ch 1 the right picture swaps the cables between the scope and the sense wire. Hence, Metalica is shown on Ch1 after swapping the leads.
HV settings | ||
Wire | Volts | |
Sense | 1500 | |
Field | -750 | |
Guard | 750 |
HV settings | ||
Wire | Volts | |
Sense | 1550 | |
Field | -775 | |
Guard | 775 |
HV settings | ||
Wire | Volts | |
Sense | 1450 | |
Field | -725 | |
Guard | 725 |