Difference between revisions of "MiniDC Signals 4-22-08"
Jump to navigation
Jump to search
| (2 intermediate revisions by the same user not shown) | |||
| Line 1: | Line 1: | ||
PreAmp is turned off.<br> | PreAmp is turned off.<br> | ||
| + | The left picture has Platika on Ch 1 the right picture swaps the cables between the scope and the sense wire. Hence, Metalica is shown on Ch1 after swapping the leads. | ||
{| border="1" |cellpadding="20" cellspacing="0 | {| border="1" |cellpadding="20" cellspacing="0 | ||
|colspan= "3" | HV settings | |colspan= "3" | HV settings | ||
| Line 13: | Line 14: | ||
|} | |} | ||
Noise: | Noise: | ||
| − | [[Image:BabyChamber_Noise_Wire4_HV_on_1500V_4-22-08.png | | + | [[Image:BabyChamber_Noise_Wire4_HV_on_1500V_4-22-08.png | 200 px]][[Image:BabyChamber_NoiseWire4_HV_on_1500V_4-22-08_1.png | 200 px]]<br> |
| − | + | ||
| − | |||
{| border="1" |cellpadding="20" cellspacing="0 | {| border="1" |cellpadding="20" cellspacing="0 | ||
| Line 29: | Line 29: | ||
|} | |} | ||
Noise: | Noise: | ||
| − | [[Image:BabyChamber_Noise_Wire4_HV_on_1550V_4-22-08.png | | + | [[Image:BabyChamber_Noise_Wire4_HV_on_1550V_4-22-08.png | 200 px]][[Image:BabyChamber_Noise_Wire4_HV_on_1550V_4-22-08_1.png | 200 px]]<br> |
| − | |||
| − | |||
{| border="1" |cellpadding="20" cellspacing="0 | {| border="1" |cellpadding="20" cellspacing="0 | ||
| Line 45: | Line 43: | ||
|} | |} | ||
Noise: | Noise: | ||
| − | [[Image:BabyChamber_Noise_Wire4_HV_on_1450V_4-22-08.png | | + | [[Image:BabyChamber_Noise_Wire4_HV_on_1450V_4-22-08.png | 200 px]][[Image:BabyChamber_Noise_Wire4_HV_on_1450V_4-22-08_1.png | 200 px]]<br> |
| − | |||
| − | |||
[http://www.iac.isu.edu/mediawiki/index.php/Mini-prototype G0 Back] | [http://www.iac.isu.edu/mediawiki/index.php/Mini-prototype G0 Back] | ||
Latest revision as of 17:33, 24 April 2008
PreAmp is turned off.
The left picture has Platika on Ch 1 the right picture swaps the cables between the scope and the sense wire. Hence, Metalica is shown on Ch1 after swapping the leads.
| HV settings | ||
| Wire | Volts | |
| Sense | 1500 | |
| Field | -750 | |
| Guard | 750 | |
| HV settings | ||
| Wire | Volts | |
| Sense | 1550 | |
| Field | -775 | |
| Guard | 775 | |
| HV settings | ||
| Wire | Volts | |
| Sense | 1450 | |
| Field | -725 | |
| Guard | 725 | |