Difference between revisions of "MiniPrototype CosmicRuns"
Line 57: | Line 57: | ||
|- | |- | ||
|Guard || 800 || 0 | |Guard || 800 || 0 | ||
+ | |} | ||
+ | |||
+ | |||
+ | [[Image:Run206_12-25-07.jpg]] | ||
+ | ==12/27/07== | ||
+ | |||
+ | Run 207: Unplugged scope and started this run | ||
+ | |||
+ | |||
+ | Drift Chamber turned on with 90/10 ArCO2 and the voltages below | ||
+ | |||
+ | {| border="1" |cellpadding="20" cellspacing="0 | ||
+ | |colspan= "3" | HV settings | ||
+ | |- | ||
+ | | Wire || Volts || current (<math>\mu</math>A) | ||
+ | |- | ||
+ | |Sense || 1600 || 19 | ||
+ | |- | ||
+ | |Field || -850 || 19 | ||
+ | |- | ||
+ | |Guard || 850 || 0 | ||
|} | |} | ||
Revision as of 17:46, 27 December 2007
Cosmic Coincidences
setup
Setup a cosmic coincidence experiment with two crossed scintillators that have the proto-type drift chambers sandwhiched between them.
Built 4 100 ns long delay cables. 2 for the PMTs and one for sense wire 7 on each of the drift chambers.
The top PMT is in channel 7 of the QDC and channel 16 of the scaler.
The Bottom PMT is on channel 8 of the QDC and channel 7 of the scaler.
Coincidence counts are recorded in channel 2 of the scaler.
Runs
Drift Chamber is off
Run 182: Ran with coincidence module in "OR" mode so if either paddle triggered the ADC was read out
Run 183: Switched coincidence module to "AND" mode and ran overnight.
12/23/07
Drift Chamber turned on with 90/10 ArCO2 and the voltages below
HV settings | ||
Wire | Volts | current ( | A)
Sense | 1500 | 19 |
Field | -800 | 19 |
Guard | 800 | 0 |
Run 204: Scope was plugged into DC output (split signal)
12/24/07
Run 206: Unplugged scope and started this run
Drift Chamber turned on with 90/10 ArCO2 and the voltages below
HV settings | ||
Wire | Volts | current ( | A)
Sense | 1500 | 19 |
Field | -800 | 19 |
Guard | 800 | 0 |
12/27/07
Run 207: Unplugged scope and started this run
Drift Chamber turned on with 90/10 ArCO2 and the voltages below
HV settings | ||
Wire | Volts | current ( | A)
Sense | 1600 | 19 |
Field | -850 | 19 |
Guard | 850 | 0 |