Line 24: Line 24:
 
==12/23/07 ==
 
==12/23/07 ==
  
 +
Drift Chamber turned on with 90/10 ArCO2 and the voltages below
 +
 +
{| border="1"  |cellpadding="20" cellspacing="0
 +
|colspan= "3" | HV settings
 +
|-
 +
| Wire ||  Volts || current (<math>\mu</math>A)
 +
|-
 +
|Sense ||  1500 || 19
 +
|-
 +
|Field ||  -800 || 19
 +
|-
 +
|Guard ||  800 || 0
 +
|}
  
 
Run 204:  Scope was plugged into DC output (split signal)
 
Run 204:  Scope was plugged into DC output (split signal)

Revision as of 00:37, 26 December 2007

Cosmic Coincidences

setup

Setup a cosmic coincidence experiment with two crossed scintillators that have the proto-type drift chambers sandwhiched between them.

Built 4 100 ns long delay cables. 2 for the PMTs and one for sense wire 7 on each of the drift chambers.


The top PMT is in channel 7 of the QDC and channel 16 of the scaler.

The Bottom PMT is on channel 8 of the QDC and channel 7 of the scaler.

Coincidence counts are recorded in channel 2 of the scaler.

Runs

Drift Chamber is off

Run 182: Ran with coincidence module in "OR" mode so if either paddle triggered the ADC was read out

Run 183: Switched coincidence module to "AND" mode and ran overnight.

12/23/07

Drift Chamber turned on with 90/10 ArCO2 and the voltages below

HV settings
Wire Volts current ([math]\mu[/math]A)
Sense 1500 19
Field -800 19
Guard 800 0

Run 204: Scope was plugged into DC output (split signal)

12/24/07

Run 206: Unplugged scope and started this run