Difference between revisions of "PbF2 CrystalNumber33"
Jump to navigation
Jump to search
Line 105: | Line 105: | ||
@16:25 [[Image:Block33 4.25pm.JPG | 200 px]] | @16:25 [[Image:Block33 4.25pm.JPG | 200 px]] | ||
+ | |||
+ | @16:35 [[Image:Block33 4.25pm.JPG | 200 px]] | ||
Revision as of 23:38, 5 December 2007
Below are the resulting transparency measurements for PbF2 block # 33
12/4/07
- Accelerator Settings
beam energy | 20 MeV |
Rep Rate: | 30 Hz |
I_peak: | 60 mA/pulse |
pulse width: | 0.1 | s (100 ns)
beam start: | 13:09 |
beam stop: | 17:09 |
- Pick-up Coil Pulse Recording (PbF2 crystal at z=30cm away)
O-scope pulses were recorded on the pick-up coil with dimensions in inches and the intensity measured in Volt
ns- Dose rate measurements (@1709 hours)
-radiation | 500 uR/hr |
-radiation: | 500 uR/hr |
- Transparency measurements (@1716 hours)
12/5/07
- Transparency measurement
- Accelerator Settings
beam energy | 20 MeV |
Rep Rate: | 30 Hz |
I_peak: | 60 mA/pulse |
pulse width: | 0.1 | s (100 ns)
beam start: | 15:00 |
beam stop: |
- Pick-up Coil Pulse Recording (PbF2 crystal at z=30cm away)
O-scope pulses were recorded on the pick-up coil with dimensions in inches and the intensity measured in Volt
ns