Difference between revisions of "PbF2 CrystalNumber33"
Jump to navigation
Jump to search
Line 52: | Line 52: | ||
@ 16:57 [[Image:Pulseblock331657.JPG | 200 px]] | @ 16:57 [[Image:Pulseblock331657.JPG | 200 px]] | ||
− | @ 17:07 [[Image: | + | @ 17:07 [[Image:Pulseblock331707.JPG | 200 px]] |
;Dose rate measurements (@1709 hours) | ;Dose rate measurements (@1709 hours) |
Revision as of 00:25, 5 December 2007
Below are the resulting transparency measurements for PbF2 block # 33
12/4/07
- Accelerator Settings
beam energy | 20 MeV |
Rep Rate: | 30 Hz |
I_peak: | 60 mA/pulse |
pulse width: | 0.1 | s (100 ns)
beam start: | 13:09 |
beam stop: |
- Pick-up Coil Pulse Recording (PbF2 crystal at z=30cm away)
O-scope pulses were recorded on the pick-up coil with dimensions in inches and the intensity measured in Volt
ns- Dose rate measurements (@1709 hours)
-radiation | 500 uR/hr |
-radiation: | 500 uR/hr |