Below are the resulting transparency measurements for PbF2 block # 16 | Below are the resulting transparency measurements for PbF2 block # 16 | ||
=12/3/07= | =12/3/07= | ||
;Accelerator Settings | |||
{| border="1" | |||
| beam energy || 20 MeV | |||
Pulse | |- | ||
| Rep Rate: || 30 Hz | |||
|- | |||
| I_peak: || 60 mA/pulse | |||
|- | |||
| pulse width:|| 0.1 <math>\mu</math>s (100 ns) | |||
|- | |||
|beam start: || 15:39 | |||
|- | |||
|beam stop: || 16:39 | |||
|} | |||
;Pick-up Coil Pulse Recording (PbF2 crystal at z=30cm away) | |||
O-scope pulses were recorded on the pick-up coil with dimensions in inches and the intensity measured in Volt <math>\times</math> ns | |||
@16:00 | |||
[[Image:PbF2_Crystal_16_Z-30cm_4pm.jpg | 200 px]] | |||
@16:05 | |||
[[Image:PbF2_Crystal_16_Z-30cm_405pm.jpg | 200 px]] | |||
@16:10 | |||
[[Image:PbF2_Crystal_16_Z-30cm_410pm.jpg | 200 px]] | |||
@16:15 | |||
[[Image:PbF2_Crystal_16_Z-30cm_415pm.jpg | 200 px]] | |||
@16:20 | |||
[[Image:PbF2_Crystal_16_Z-30cm_420pm.jpg | 200 px]] | |||
@16:25 | |||
[[Image:PbF2_Crystal_16_Z-30cm_425pm.jpg | 200 px]] | |||
@16:30 | |||
[[Image:PbF2_Crystal_16_Z-30cm_430pm.jpg | 200 px]] | |||
@16:39 | |||
[[Image:PbF2_Crystal_16_Z-30cm_439pm.jpg | 200 px]] | |||
;Dose rate measurements (@1643 hours) | |||
{| border="1" | |||
| <math>\gamma</math>-radiation || 3.5 mR/hr | |||
|- | |||
| <math>\beta</math>-radiation: || 12 mR/hr | |||
|} | |||
;Dose rate measurements (@1532 hours) | |||
{| border="1" | |||
| <math>\gamma</math>-radiation || 3 mR/hr | |||
|- | |||
| <math>\beta</math>-radiation: || 7 mR/hr | |||
|} | |||
=12/4/07= | =12/4/07= | ||
Transparency measurements (@0957 hours) | |||
[[Image:Block16.JPG | 500 px]] [[Image:Block1690deg.JPG | 500 px]] | |||
Under Blue light for 19 hours before next irradiation. | |||
=12/5/07= | =12/5/07= | ||
;Accelerator Settings | |||
{| border="1" | |||
| beam energy || 20 MeV | |||
|- | |||
| Rep Rate: || 30 Hz | |||
|- | |||
| I_peak: || 60 mA/pulse | |||
|- | |||
| pulse width:|| 0.1 <math>\mu</math>s (100 ns) | |||
|- | |||
|beam start: || 08:38 | |||
|- | |||
|beam stop: || 10:38 | |||
|} | |||
;Pick-up Coil Pulse Recording (PbF2 crystal at z=30cm away) | |||
O-scope pulses were recorded on the pick-up coil with dimensions in inches and the intensity measured in Volt <math>\times</math> ns | |||
@8:57 [[Image:Pulseb16857.JPG | 200 px]] | |||
@9:07 [[Image:Pulseb16907.JPG | 200 px]] | |||
@9:17 [[Image:Pulseb16917.JPG | 200 px]] | |||
@9:27 [[Image:Pulseb16927.JPG | 200 px]] | |||
@9:37 [[Image:Pulseb16937.JPG | 200 px]] | |||
@9:47 [[Image:Pulseb16947.JPG | 200 px]] | |||
@9:57 [[Image:Pulseb16957.JPG | 200 px]] | |||
@10:07 [[Image:Pulseb161007.JPG | 200 px]] | |||
@10:17 [[Image:Pulseb161017.JPG | 200 px]] | |||
@10:27 [[Image:Pulseb161027.JPG | 200 px]] | |||
;Dose rate measurements (@1040 hours) | |||
{| border="1" | |||
| <math>\gamma</math>-radiation || 2 mR/hr | |||
|- | |||
| <math>\beta</math>-radiation: || 3 mR/hr | |||
|} | |||
After: [[Image:DSCF1565.JPG | 500 px]] | |||
Just after 2nd irradiation (2 hours). Light brown color (translucent). | |||
Latest revision as of 01:44, 7 December 2007
Below are the resulting transparency measurements for PbF2 block # 16
12/3/07
- Accelerator Settings
| beam energy | 20 MeV |
| Rep Rate: | 30 Hz |
| I_peak: | 60 mA/pulse |
| pulse width: | 0.1 [math]\displaystyle{ \mu }[/math]s (100 ns) |
| beam start: | 15:39 |
| beam stop: | 16:39 |
- Pick-up Coil Pulse Recording (PbF2 crystal at z=30cm away)
O-scope pulses were recorded on the pick-up coil with dimensions in inches and the intensity measured in Volt [math]\displaystyle{ \times }[/math] ns
- Dose rate measurements (@1643 hours)
| [math]\displaystyle{ \gamma }[/math]-radiation | 3.5 mR/hr |
| [math]\displaystyle{ \beta }[/math]-radiation: | 12 mR/hr |
- Dose rate measurements (@1532 hours)
| [math]\displaystyle{ \gamma }[/math]-radiation | 3 mR/hr |
| [math]\displaystyle{ \beta }[/math]-radiation: | 7 mR/hr |
12/4/07
Transparency measurements (@0957 hours)
Under Blue light for 19 hours before next irradiation.
12/5/07
- Accelerator Settings
| beam energy | 20 MeV |
| Rep Rate: | 30 Hz |
| I_peak: | 60 mA/pulse |
| pulse width: | 0.1 [math]\displaystyle{ \mu }[/math]s (100 ns) |
| beam start: | 08:38 |
| beam stop: | 10:38 |
- Pick-up Coil Pulse Recording (PbF2 crystal at z=30cm away)
O-scope pulses were recorded on the pick-up coil with dimensions in inches and the intensity measured in Volt [math]\displaystyle{ \times }[/math] ns
- Dose rate measurements (@1040 hours)
| [math]\displaystyle{ \gamma }[/math]-radiation | 2 mR/hr |
| [math]\displaystyle{ \beta }[/math]-radiation: | 3 mR/hr |
After:
Just after 2nd irradiation (2 hours). Light brown color (translucent).