Difference between revisions of "PbF2 CrystalNumber16"
Jump to navigation
Jump to search
| Line 114: | Line 114: | ||
| <math>\beta</math>-radiation: || 3 mR/hr | | <math>\beta</math>-radiation: || 3 mR/hr | ||
|} | |} | ||
| + | |||
| + | |||
| + | After: [[Image:DSCF1565.JPG | 500 px]] | ||
Revision as of 17:51, 5 December 2007
Below are the resulting transparency measurements for PbF2 block # 16
12/3/07
- Accelerator Settings
| beam energy | 20 MeV |
| Rep Rate: | 30 Hz |
| I_peak: | 60 mA/pulse |
| pulse width: | 0.1 s (100 ns) |
| beam start: | 15:39 |
| beam stop: | 16:39 |
- Pick-up Coil Pulse Recording (PbF2 crystal at z=30cm away)
O-scope pulses were recorded on the pick-up coil with dimensions in inches and the intensity measured in Volt ns
- Dose rate measurements (@1643 hours)
| -radiation | 3.5 mR/hr |
| -radiation: | 12 mR/hr |
- Dose rate measurements (@1532 hours)
| -radiation | 3 mR/hr |
| -radiation: | 7 mR/hr |
12/4/07
Dose rate measurements (@0957 hours)
Under Blue light for 19 hours before next irradiation.
12/5/07
- Accelerator Settings
| beam energy | 20 MeV |
| Rep Rate: | 30 Hz |
| I_peak: | 60 mA/pulse |
| pulse width: | 0.1 s (100 ns) |
| beam start: | 08:38 |
| beam stop: | 10:38 |
- Pick-up Coil Pulse Recording (PbF2 crystal at z=30cm away)
O-scope pulses were recorded on the pick-up coil with dimensions in inches and the intensity measured in Volt ns
- Dose rate measurements (@1040 hours)
| -radiation | 2 mR/hr |
| -radiation: | 3 mR/hr |