Below are the resulting transparency measurements for PbF2 block # 16

12/3/07

Accelerator Settings
beam energy 20 MeV
Rep Rate: 30 Hz
I_peak: 60 mA/pulse
pulse width: 0.1 [math]\displaystyle{ \mu }[/math]s (100 ns)
beam start: 15:39
beam stop: 16:39
Pick-up Coil Pulse Recording (PbF2 crystal at z=30cm away)

O-scope pulses were recorded on the pick-up coil with dimensions in inches and the intensity measured in Volt [math]\displaystyle{ \times }[/math] ns

@16:00

@16:05

@16:10

@16:15

@16:20

@16:25

@16:30

@16:39

Dose rate measurements (@1643 hours)
[math]\displaystyle{ \gamma }[/math]-radiation 3.5 mR/hr
[math]\displaystyle{ \beta }[/math]-radiation: 12 mR/hr
Dose rate measurements (@1532 hours)
[math]\displaystyle{ \gamma }[/math]-radiation 3 mR/hr
[math]\displaystyle{ \beta }[/math]-radiation: 7 mR/hr

12/4/07

Dose rate measurements (@0957 hours)

Under Blue light for 19 hours before next irradiation.

12/5/07

Accelerator Settings
beam energy 20 MeV
Rep Rate: 30 Hz
I_peak: 60 mA/pulse
pulse width: 0.1 [math]\displaystyle{ \mu }[/math]s (100 ns)
beam start: 08:38
beam stop: 10:38
Pick-up Coil Pulse Recording (PbF2 crystal at z=30cm away)

O-scope pulses were recorded on the pick-up coil with dimensions in inches and the intensity measured in Volt [math]\displaystyle{ \times }[/math] ns

@8:57

@9:07

@9:17

@9:27

@9:37

@9:47

@9:57

@10:07

@10:17

@10:27


Dose rate measurements (@1040 hours)
[math]\displaystyle{ \gamma }[/math]-radiation 2 mR/hr
[math]\displaystyle{ \beta }[/math]-radiation: 3 mR/hr


After: