| Line 84: | 
Line 84: | 
|   |  |   |  | 
|   | @9:07 [[Image:Pulseb16907.JPG | 200 px]]  |   | @9:07 [[Image:Pulseb16907.JPG | 200 px]]  | 
|   | + |  | 
|   | + | @9:17 [[Image:Pulseb16917.JPG | 200 px]]  | 
		Revision as of 16:21, 5 December 2007
Below are the resulting transparency measurements for PbF2 block # 16
12/3/07
- Accelerator Settings
 
| beam energy | 
20 MeV
 | 
| Rep Rate: | 
30 Hz
 | 
| I_peak: | 
60 mA/pulse
 | 
| pulse width: | 
0.1 [math]\mu[/math]s (100 ns)
 | 
| beam start: | 
15:39
 | 
| beam stop: | 
16:39
 | 
- Pick-up Coil Pulse Recording (PbF2 crystal at z=30cm away)
 
O-scope pulses were recorded on the pick-up coil with dimensions in inches and the intensity measured in Volt [math]\times[/math] ns
@16:00
@16:05
@16:10
@16:15
@16:20
@16:25
@16:30
@16:39
- Dose rate measurements (@1643 hours)
 
| [math]\gamma[/math]-radiation | 
3.5 mR/hr
 | 
| [math]\beta[/math]-radiation: | 
12 mR/hr
 | 
- Dose rate measurements (@1532 hours)
 
| [math]\gamma[/math]-radiation | 
3 mR/hr
 | 
| [math]\beta[/math]-radiation: | 
7 mR/hr
 | 
12/4/07
12/5/07
- Accelerator Settings
 
| beam energy | 
20 MeV
 | 
| Rep Rate: | 
30 Hz
 | 
| I_peak: | 
60 mA/pulse
 | 
| pulse width: | 
0.1 [math]\mu[/math]s (100 ns)
 | 
| beam start: | 
08:38
 | 
| beam stop: | 
 | 
- Pick-up Coil Pulse Recording (PbF2 crystal at z=30cm away)
 
O-scope pulses were recorded on the pick-up coil with dimensions in inches and the intensity measured in Volt [math]\times[/math] ns
@8:57 
@9:07 
@9:17