Setting address
Address | |
Pin | Setting |
SW-A32L | 3 |
SW-A32U | 8 |
SW-A24L | 3 |
SW-A24U | 8 |
SW-A16 | 3 |
There was also a of jumpers labeled "EN_A16, "EN_A24" and "EN_A32". The factory default setting was "EN_A32" so I moved the jumper to "EN_16".
I left the base address unchanged. Which means for A16 addressing mode the address will be 0x3800.
Test Communication from ROC console
From the ROC console (minicom window) I tried talking to the SIS3610 using the library function "s3610Init"
-> s3610Init 0x3800 Initialized SIS3610 ID 0 at address 0x91003800 value = 0 = 0x0
The next test was to try and turn the user LED (labeled "U" on the front pannel) on and off.
From the ROC console I typed
-> s3610SetLED value = 0 = 0x0
and I saw the green LED light up
I then typed
-> s3610ClearLED value = 0 = 0x0
and I saw it turn off