Difference between revisions of "SIS3600 Trigger Supervisor"
Jump to navigation
Jump to search
Line 18: | Line 18: | ||
|SW-A16 || 3 | |SW-A16 || 3 | ||
|} | |} | ||
+ | |||
+ | |||
+ | There was also a of jumpers labeled "EN_A16, "EN_A24" and "EN_A32". The factory default setting was "EN_A32" so I moved the jumper to "EN_16". | ||
+ | |||
+ | I left the base address unchanged. Which means for A16 addressing mode the address will be 0x3800. |
Revision as of 17:43, 23 October 2007
Setting address
Address | |
Pin | Setting |
SW-A32L | 3 |
SW-A32U | 8 |
SW-A24L | 3 |
SW-A24U | 8 |
SW-A16 | 3 |
There was also a of jumpers labeled "EN_A16, "EN_A24" and "EN_A32". The factory default setting was "EN_A32" so I moved the jumper to "EN_16".
I left the base address unchanged. Which means for A16 addressing mode the address will be 0x3800.