Difference between revisions of "CLAS apparatus"
Line 21: | Line 21: | ||
The Nuclear Magnetic Resonance(NMR) coils were wrapped around the outside surface of the cells in order to reduce the background, maximize the amount of ammonia in the target cells and monitor the polarization of the target. The geometry of the NMR coils were chosen so that they would be maximally sensitive to the target polarization. They were made out of CuNi material with a thickness of 0.15 mm and bent into rectangular loops. The temperature sensors(thermocouples, RuO resistors) were attached to the target insert at different locations to monitor the temperature of the target materials.<br> | The Nuclear Magnetic Resonance(NMR) coils were wrapped around the outside surface of the cells in order to reduce the background, maximize the amount of ammonia in the target cells and monitor the polarization of the target. The geometry of the NMR coils were chosen so that they would be maximally sensitive to the target polarization. They were made out of CuNi material with a thickness of 0.15 mm and bent into rectangular loops. The temperature sensors(thermocouples, RuO resistors) were attached to the target insert at different locations to monitor the temperature of the target materials.<br> | ||
− | [[Image:The_Target_Insert.gif]]<br> | + | [[Image:The_Target_Insert.gif|500px]]<br> |
A second target insert was designed and built by the Jefferson Lab Polarized Target Group to measure the background using solid <math>N^{15}</math>. The first measurements of electron scattering from <math>N^{15}</math> target provided the data which was subtracted from the <math>NH_3</math> scattering data in order to eliminate the contribution of the <math>N^{15}</math>. The insert cell is made out of a Torlon of 15.7 mm in diameter and 12.7 mm in length. Both sides of the cell are covered by kapton windows. The target cell was filled with isotopically enriched <math>N^{15}</math> gas at room temperature and the insert was located into the target chamber in order to cool it by LHe, causing the gas to condense. To avert the target from freezing a heater wire was wrapped around the filling tubes and plugging the tubes before the cell was filled with the gas.<br> | A second target insert was designed and built by the Jefferson Lab Polarized Target Group to measure the background using solid <math>N^{15}</math>. The first measurements of electron scattering from <math>N^{15}</math> target provided the data which was subtracted from the <math>NH_3</math> scattering data in order to eliminate the contribution of the <math>N^{15}</math>. The insert cell is made out of a Torlon of 15.7 mm in diameter and 12.7 mm in length. Both sides of the cell are covered by kapton windows. The target cell was filled with isotopically enriched <math>N^{15}</math> gas at room temperature and the insert was located into the target chamber in order to cool it by LHe, causing the gas to condense. To avert the target from freezing a heater wire was wrapped around the filling tubes and plugging the tubes before the cell was filled with the gas.<br> | ||
− | [[Image:The_N_15_Insert_Stick.gif]]<br> | + | [[Image:The_N_15_Insert_Stick.gif|500px]]<br> |
*The Microwave System | *The Microwave System |
Revision as of 20:27, 14 July 2008
Apparatus
Target
In EG1b experiment, the polarized targets
The Target System
- The Magnet
The 5 T magnetic field parallel to the beam direction is produced by a superconducting pair of Helmholtz coils, which are cooled by the liquid helium reservoir located outside the CLAS detector. The uniformity of the field is varying less than
- The Evaporation Refrigerator
The target is cooled to ~ 1 K using the helium, which is supplied from the 1 K
- The Target Chamber and the Minicup
- The Target Inserts
The target insert was designed and built by the INFN of Genova. The target cells with a thickness of 0.2 mm were made out of polychlorotrifluoroethylene (PCTFE), it is a hydrogen-free material and would not produce an NMR background, also it is not effected by radiation as much as other materials. Each target cell is 15 mm in diameter and 10 mm in length sealed by a 0.025 mm thick aluminum foil at entrance window and 0.05 mm thick kapton foil at exit window. LHe in the target cells are supplied from the tiny holes which are located at the exit window and the ammonia beads.
The target insert has the four target cells. Two of them were filled with ammonia beads: the top one with and the other one with . was followed by carbon ( ) disk with a thickness of 2.3 mm and the fourth cell was left empty. The carbon and the empty cells were used to measure background.
The Nuclear Magnetic Resonance(NMR) coils were wrapped around the outside surface of the cells in order to reduce the background, maximize the amount of ammonia in the target cells and monitor the polarization of the target. The geometry of the NMR coils were chosen so that they would be maximally sensitive to the target polarization. They were made out of CuNi material with a thickness of 0.15 mm and bent into rectangular loops. The temperature sensors(thermocouples, RuO resistors) were attached to the target insert at different locations to monitor the temperature of the target materials.
A second target insert was designed and built by the Jefferson Lab Polarized Target Group to measure the background using solid
- The Microwave System
The target materials used in the EG1b experiments were
To prepare the target material, ammonia gas was frozen at 77 K and then crushed into little
pieces, about 1-3 mm in diameter. In the case of deuterated ammonia was used. The target are kept in solid form during the experiment by liquid helium.
Tracking System
Scintillators
The CEBAF Large Acceptance Spectrometer (CLAS) is equipped with 288 scintillator counters. The purpose of the scintillator is to determine the time of flight for the charged particles and to trigger it in coincidence with another detector system for the particle identification. The time of flight system is built so that time resolution at small polar angles
The time of flight system is located between the Cherenkov detectors and electromagnetic calorimeters. The scintillator strips(BC_408) are located perpendicularly to the average particle trajectory with an angular polar coverage of 1.5 degrees. Each sector of The CLAS detector consists of 48 strips with a thickness of 5.08 cm. The length of the scintillators varies from 30 cm to 450 cm and the width is between 15 cm at small polar angles and 22 cm for the large angles.
Each scintillator of the CLAS detector is surrounded with a photomultiplier tube. When particle hits the scintillator strip, part of its energy can excite atoms in the scintillator which in the end produces light(visible). The produced light is transmitted to the photomultiplier tubes by light guides.
For each photomultiplier tube the time and pulse height are measured. This is important to evaluate the time-walk correction and in addition, the measure of the pulse height gives information on the energy released by the crossing particle.
Cherenkov detector
The CLAS Cherenkov detector is a threshold gas counter filled with perfluorobutane
As a light collector were used the system of mirrors , the light collecting cones and photomultiplier tubes(PMTs). In the extreme regions of the angular acceptance of the spectrometer the number of detected photoelectrons is too low. To get acceptable efficiency of the detector in these regions were placed photomultiplier tubes.
The charged particle trajectories are in planes of almost constant azimuthal angle, because of the toroidal configuration of the magnetic field. Under this conditions, the light collection can be designed to focus the light in the azimuthal angle direction. However, the polar angle is constant. Each of the six sectors was divided into 18 regions of the polar angle
The optical elements of each
The photomultiplier tubes were surrounded with high permeability magnetic fields,because they were located in the fringe field region of the spectrometer(??????).
Below is shown the scheme of CLAS detector
Calorimeter
The CLAS detectur contains 8 modules of electromagnetic calorimeter. A calorimeter is a device that measures the total energy deposited by a crossing particle. They are useful in detecting neutral particles and distinguishing between electrons and hadrons due to their different mechanism of depositing energy.The CLAS calorimeter has three main functions:
1) detection of electrons at energies above 0.5 GeV;
2) detection of photons with energies higher than 0.2 GeV;
3) detection of neutrons, with discrimination between photon and neutrons using time-of-flight technique.
6 calorimeter modules of the CLAS detector are placed in each sector in the forward region (polar angle of 10-45 degrees, forward angle calorimeter), while the other two modules are located at large angles in sectors 1 and 2(50-70 degrees, large angle calorimeter). The forward calorimeter has a lead/scintillator thickness ratio 0.2, with 40 cm of scintillators and 8 cm of lead per module. The lead-scintillator sandwich is shaped as a equlaterial triangle in order to match the hexagonal geometry of the CLAS detector. It is made of 39 layers of a 10 mm BC_412 scintillator and lead sheet of thickness of 2.2 mm. Each scintillator layer contains 36 strips parallel to one side of the triangle, with this configuration each orientation is rotated by 120 degrees from another one. This gives three views each containing 13 layers providing stereo information of the location of the energy deposition.
To improve hadron identification, there was provided longitudinal sampling of the shower. Each set of 13 layers were subdivided into an inner 5 layers and outer 8 layers stack.