Difference between revisions of "CLAS apparatus"
(→Target) |
(→Target) |
||
Line 1: | Line 1: | ||
Apparatus | Apparatus | ||
=Target= | =Target= | ||
− | The target materials used in the EG1b experiments were <math> NH_3</math>, <math>ND_3</math>, <math>C^{12}</math>, and <math>N^{15}</math>. The first one was used | + | The target materials used in the EG1b experiments were <math> NH_3</math>, <math>ND_3</math>, <math>C^{12}</math>, and <math>N^{15}</math>. The first one was used as a polarized proton target and the second provided polarized Deuterons. These materials satisfy several conditions which are suitable for scattering experiments. Ammonia targets produce high polarization and are resistant to radiation damage(it will be changed) which can be easily repaired by an annealing process. Also,it has a high ratio of free nucleons(3/18).<br> |
− | + | To prepare the target material, ammonia gas was frozen at 77 K and then crushed into little | |
− | pieces, about 1-3 mm in diameter | + | pieces, about 1-3 mm in diameter. In the case of <math>ND_3</math> deuterated ammonia was used. The target are kept in solid form during the experiment by liquid helium. |
=Tracking System= | =Tracking System= |
Revision as of 02:50, 15 August 2007
Apparatus
Target
The target materials used in the EG1b experiments were
To prepare the target material, ammonia gas was frozen at 77 K and then crushed into little
pieces, about 1-3 mm in diameter. In the case of deuterated ammonia was used. The target are kept in solid form during the experiment by liquid helium.
Tracking System
Scintillators
Cherenkov detector
The CLAS Cherenkov detector is a threshold gas counter. It was filled with perfluorobutane
As a light collector were used the system of mirrors , the light collecting cones and photomultiplier tubes(PMTs). In the extreme regions of the angular acceptance of the spectrometer the number of detected photoelectrons is too low. To get acceptable efficiency of the detector in these regions were placed photomultiplier tubes.
The charged particle trajectories are in planes of almost constant azimuthal angle, because of the toroidal configuration of the magnetic field. Under this conditions, the light collection can be designed to focus the light in the azimuthal angle direction. However, the polar angle is constant. Each of the six sectors was divided into 18 regions of the polar angle
The optical elements of each
The photomultiplier tubes were surrounded with high permeability magnetic fields,because they were located in the fringe field region of the spectrometer(??????).