| Run Number || Configuration || CF-252 Source || Counts || Run Time (Sec) || Count Rate (Hz) | | Run Number || Configuration || CF-252 Source || Counts || Run Time (Sec) || Count Rate (Hz) | ||
|- | |- | ||
− | | 1 || Unshielded detector at +800V, no discriminator or amplifier || Yes || | + | | 1 || Unshielded detector at +800V, no discriminator or amplifier || Yes || || 60 || |
|- | |- | ||
− | | 2 || Unshielded detector at +800V, no discriminator or amplifier || Yes || | + | | 2 || Unshielded detector at +800V, no discriminator or amplifier || Yes || || 60 || |
|- | |- | ||
− | | 3 || Unshielded detector at +800V, no discriminator or amplifier || Yes || | + | | 3 || Unshielded detector at +800V, no discriminator or amplifier || Yes || || 60 || |
|- | |- | ||
− | | 4 || Unshielded detector at +800V, no discriminator or amplifier || Yes || | + | | 4 || Unshielded detector at +800V, no discriminator or amplifier || Yes || || 60 || |
|- | |- | ||
− | | 5 || Unshielded detector at +800V, no discriminator or amplifier || Yes || | + | | 5 || Unshielded detector at +800V, no discriminator or amplifier || Yes || || 60 || |
|- | |- | ||
− | | 6 || Unshielded detector at +800V, no discriminator or amplifier || Yes || | + | | 6 || Unshielded detector at +800V, no discriminator or amplifier || Yes || || 60 || |
|- | |- | ||
− | | 7 || Unshielded detector at +800V, no discriminator or amplifier || Yes || | + | | 7 || Unshielded detector at +800V, no discriminator or amplifier || Yes || || 60 || |
|- | |- | ||
− | | 8 || Unshielded detector at +800V, no discriminator or amplifier || Yes || | + | | 8 || Unshielded detector at +800V, no discriminator or amplifier || Yes || || 60 || |
|- | |- | ||
− | | 9 || Unshielded detector at +800V, no discriminator or amplifier || Yes || | + | | 9 || Unshielded detector at +800V, no discriminator or amplifier || Yes || || 60 || |
|- | |- | ||
− | | 10 || Unshielded detector at +800V, no discriminator or amplifier || Yes || | + | | 10 || Unshielded detector at +800V, no discriminator or amplifier || Yes || || 60 || |
|- | |- | ||
|} | |} |
Revision as of 20:03, 14 May 2021
Preliminary Measurements
Run Number Configuration CF-252 Source Counts Run Time (Sec) Count Rate (Hz) 1 Unshielded detector at +800V, no discriminator or amplifier No 49 60 2 Unshielded detector at +800V, no discriminator or amplifier No 46 60 3 Unshielded detector at +800V, no discriminator or amplifier No 46 60 4 Unshielded detector at +800V, no discriminator or amplifier No 36 60 5 Unshielded detector at +800V, no discriminator or amplifier No 46 60 6 Unshielded detector at +800V, no discriminator or amplifier No 42 60 7 Unshielded detector at +800V, no discriminator or amplifier No 45 60 8 Unshielded detector at +800V, no discriminator or amplifier No 47 60 9 Unshielded detector at +800V, no discriminator or amplifier No 54 60 10 Unshielded detector at +800V, no discriminator or amplifier No 41 60
Run Number Configuration CF-252 Source Counts Run Time (Sec) Count Rate (Hz) 1 Unshielded detector at +800V, no discriminator or amplifier Yes 60 2 Unshielded detector at +800V, no discriminator or amplifier Yes 60 3 Unshielded detector at +800V, no discriminator or amplifier Yes 60 4 Unshielded detector at +800V, no discriminator or amplifier Yes 60 5 Unshielded detector at +800V, no discriminator or amplifier Yes 60 6 Unshielded detector at +800V, no discriminator or amplifier Yes 60 7 Unshielded detector at +800V, no discriminator or amplifier Yes 60 8 Unshielded detector at +800V, no discriminator or amplifier Yes 60 9 Unshielded detector at +800V, no discriminator or amplifier Yes 60 10 Unshielded detector at +800V, no discriminator or amplifier Yes 60