Line 41: | Line 41: | ||
||0.1% Sample Se/Soil Pure Witness Selenium || 5/23/17 (30 min) || 07/25/17 (16:32:52) || 834.41 <math> \pm </math> 25.61 || 1201.58 <math> \pm </math> 36.88 | ||0.1% Sample Se/Soil Pure Witness Selenium || 5/23/17 (30 min) || 07/25/17 (16:32:52) || 834.41 <math> \pm </math> 25.61 || 1201.58 <math> \pm </math> 36.88 | ||
|- | |- | ||
+ | ||0.1% Sample Se/Soil Front Inner Ni Foil || 5/23/17 (30 min) || 5/24/17 (14:25:39 || | ||
|} | |} |
Revision as of 17:52, 27 July 2018
Analysis
The detection limit was found by using "fixed fit" activity values (
) (half life curves with the slope forced to be the accepted half life) and its associated error (|Data Fit - Fixed Fit|). Once those values have been found, then an average value was taken between irradiations with similar beam times. Normalization constants were found for the two averaged values for the activity by computing
Once the average was found, the next step was to normalize the activities to the longest beam time with
Where
is the longest irradiation time and is the actual irradiation time.If
was not normalized to the longest beam time (as it was the longest beam time) the following ratio was computed
If
was found, then the ratio was computed as
50% Excluded
For this analysis, begin by using the first measurement of the Se-75 line and using the standard exponential decay equation to correct it and its error back to the time of beam off. Below is a table of the Se-75 (120d) corrected measurements
Sample | Activated (total beam time) | Counted | Fully Thesis Corrected Rate @ 1st Measurement (Hz) | Decay Corrected Activity |
10% Se/Soil Mixture | 5/23/17 and 5/24/17 (83 min) | 07/18/17 (16:25:44) | 3109.68 | 95.394280.08 | 131.29
10% Se/Soil Pure Witness selenium | 5/23/17 and 5/24/17 (83 min) | 8/1/17 (16:05:51) | 4161.29 | 127.636210.50 | 190.48
10% Se/Soil Front Inner Ni Foil | 5/23/17 (1h) | 5/23/17 (15:52:21) | 385955 | 23488.8425064.36 | 25868.95
1% Sample Se/Soil Mixture | 5/23/17 (1h) | 6/23/17 (16:39:03) | 2233.33 | 68.522675.24 | 82.08
1% Sample Se/Soil Pure Witness selenium | 5/23/17 (1h) | 7/20/17 (16:39:46) | 3840.86 | 117.815379.43 | 165.00
1% Sample Se/Soil Front Inner Ni Foil | 5/23/17 (1h) | 5/23/17 (17:59:39) | 261461 | 16045.7293170.78 | 17991.71
0.1% Sample Se/Soil Mixture | 5/23/17 (30 min) | 6/19/17 (18:25:18) | 849.46 | 26.07993.59 | 30.49
0.1% Sample Se/Soil Pure Witness Selenium | 5/23/17 (30 min) | 07/25/17 (16:32:52) | 834.41 | 25.611201.58 | 36.88
0.1% Sample Se/Soil Front Inner Ni Foil | 5/23/17 (30 min) | 5/24/17 (14:25:39 |