=Hardware List=
+
__NOTOC__
==He3 tube==
+
=Experimental Setup=
===Purpose===
+
[[File:DAF_He3_Tube_Experimental_Setup.png|800px]]
 +
=Electronics=
 +
==Flowchart==
 +
[[File:DAF_He3_Tube_Plateau_Study_Hardware_Flowchart.png|800px]]
 +
==List==
 +
===He3 tube===
 +
====Purpose====
 
Neutron Detector. Provides the signal of interest.
 
Neutron Detector. Provides the signal of interest.
===Inputs===
+
====Inputs====
 
*None
 
*None
===Outputs===
+
====Outputs====
 
*Signal
 
*Signal
===Settings===
+
====Settings====
 
*None
 
*None
==Ortec 142PC Preamplifier==
+
===Ortec 142PC Preamplifier===
===Purpose===
+
====Purpose====
 
Amplifies the signal above the noise level.
 
Amplifies the signal above the noise level.
===Inputs===
+
====Inputs====
 
*Power
 
*Power
 
*Signal
 
*Signal
 
*Bias
 
*Bias
===Outputs===
+
====Outputs====
 
*Time Signal
 
*Time Signal
 
*Energy Signal
 
*Energy Signal
===Settings===
+
====Settings====
 
*None
 
*None
==Ortec 459 Bias Supply==
+
===Ortec 459 Bias Supply===
===Purpose===
+
====Purpose====
 
Provides the bias voltage to the preamp.
 
Provides the bias voltage to the preamp.
===Inputs===
+
====Inputs====
 
*None
 
*None
===Outputs===
+
====Outputs====
 
*Bias Supply
 
*Bias Supply
===Settings===
+
====Settings====
 
*Output Voltage
 
*Output Voltage
==Ortec 672 Spectroscopy Amplifier==
+
===Ortec 672 Spectroscopy Amplifier===
===Purpose===
+
====Purpose====
 
Amplify, shape, and invert the signal.
 
Amplify, shape, and invert the signal.
===Inputs===
+
====Inputs====
 
*Norm
 
*Norm
 
*Diff Ref
 
*Diff Ref
===Outputs===
+
====Outputs====
 
*Unipolar
 
*Unipolar
 
*Bipolar
 
*Bipolar
===Settings===
+
====Settings====
 
*Coarse Gain
 
*Coarse Gain
 
*Fine Gain
 
*Fine Gain
Line 47: Line 53:
 
*BLR
 
*BLR
 
*Input
 
*Input
==Ortec 871 Timer Counter==
+
===Ortec 871 Timer Counter===
===Purpose===
+
====Purpose====
 
Count the signal pulses.
 
Count the signal pulses.
===Inputs===
+
====Inputs====
 
*Positive
 
*Positive
 
*Negative
 
*Negative
===Outputs===
+
====Outputs====
 
*None
 
*None
===Settings===
+
====Settings====
 
*Base Coefficient
 
*Base Coefficient
 
*Power
 
*Power
 
*Time Base
 
*Time Base
 
*Dwell
 
*Dwell
==CAEN N110 Dual Attenuator==
+
===CAEN N110 Dual Attenuator===
===Purpose===
+
====Purpose====
 
Attenuate the signal into a useful region.
 
Attenuate the signal into a useful region.
===Inputs===
+
====Inputs====
 
*In
 
*In
===Outputs===
+
====Outputs====
 
*Out
 
*Out
===Settings===
+
====Settings====
 
*None
 
*None
==CAEN N841 Leading Edge Discriminator==
+
===CAEN N841 Leading Edge Discriminator===
===Purpose===
+
====Purpose====
 
Distinguish between signal and noise.
 
Distinguish between signal and noise.
===Inputs===
+
====Inputs====
 
*Channels 0-15
 
*Channels 0-15
===Outputs===
+
====Outputs====
 
*Channels 0-15 (NIM Logic Pulse)
 
*Channels 0-15 (NIM Logic Pulse)
===Settings===
+
====Settings====
 
*Threshold
 
*Threshold
 
*Pulse Width
 
*Pulse Width
==CAEN N93B Dual Timer==
+
===CAEN N93B Dual Timer===
===Purpose===
+
====Purpose====
 
Provide dead time to prevent double counting.
 
Provide dead time to prevent double counting.
===Inputs===
+
====Inputs====
 
*Start
 
*Start
 
*Veto
 
*Veto
===Outputs===
+
====Outputs====
 
*Out
 
*Out
===Settings===
+
====Settings====
 
*Coarse Pulse Width
 
*Coarse Pulse Width
 
*Fine Pulse Width
 
*Fine Pulse Width
==Tektronic DPO 4104 Digital Phosphor Oscilloscope==
+
===Tektronic DPO 4104 Digital Phosphor Oscilloscope===
===Purpose===
+
====Purpose====
 
View hits / troubleshoot system.
 
View hits / troubleshoot system.
===Inputs===
+
====Inputs====
 
*Channels 1-4
 
*Channels 1-4
===Outputs===
+
====Outputs====
 
*None
 
*None
===Settings===
+
====Settings====
 
*Too many to put here.
 
*Too many to put here.
=Flowchart=
+
 
[[File:DAF_He3_Tube_Plateau_Study_Hardware_Flowchart.png|800px]]
+
=Main Page=
 +
[[User:Friadavi]]

Latest revision as of 17:36, 29 June 2018

Experimental Setup

DAF He3 Tube Experimental Setup.png

Electronics

Flowchart

DAF He3 Tube Plateau Study Hardware Flowchart.png

List

He3 tube

Purpose

Neutron Detector. Provides the signal of interest.

Inputs

  • None

Outputs

  • Signal

Settings

  • None

Ortec 142PC Preamplifier

Purpose

Amplifies the signal above the noise level.

Inputs

  • Power
  • Signal
  • Bias

Outputs

  • Time Signal
  • Energy Signal

Settings

  • None

Ortec 459 Bias Supply

Purpose

Provides the bias voltage to the preamp.

Inputs

  • None

Outputs

  • Bias Supply

Settings

  • Output Voltage

Ortec 672 Spectroscopy Amplifier

Purpose

Amplify, shape, and invert the signal.

Inputs

  • Norm
  • Diff Ref

Outputs

  • Unipolar
  • Bipolar

Settings

  • Coarse Gain
  • Fine Gain
  • Uni Shaping
  • Shaping Time
  • PZ
  • BLR
  • Input

Ortec 871 Timer Counter

Purpose

Count the signal pulses.

Inputs

  • Positive
  • Negative

Outputs

  • None

Settings

  • Base Coefficient
  • Power
  • Time Base
  • Dwell

CAEN N110 Dual Attenuator

Purpose

Attenuate the signal into a useful region.

Inputs

  • In

Outputs

  • Out

Settings

  • None

CAEN N841 Leading Edge Discriminator

Purpose

Distinguish between signal and noise.

Inputs

  • Channels 0-15

Outputs

  • Channels 0-15 (NIM Logic Pulse)

Settings

  • Threshold
  • Pulse Width

CAEN N93B Dual Timer

Purpose

Provide dead time to prevent double counting.

Inputs

  • Start
  • Veto

Outputs

  • Out

Settings

  • Coarse Pulse Width
  • Fine Pulse Width

Tektronic DPO 4104 Digital Phosphor Oscilloscope

Purpose

View hits / troubleshoot system.

Inputs

  • Channels 1-4

Outputs

  • None

Settings

  • Too many to put here.