==Ortec 459 Bias Supply==
 
==Ortec 459 Bias Supply==
 +
===Purpose===
 +
Provides the bias voltage to the preamp.
 +
===Inputs===
 +
*None
 +
===Outputs===
 +
*Bias Supply
 +
===Settings===
 +
*Output Voltage
 
==Ortec 672 Spectroscopy Amplifier==
 
==Ortec 672 Spectroscopy Amplifier==
 +
===Purpose===
 +
Amplify, shape, and invert the signal.
 +
===Inputs===
 +
*Norm
 +
*Diff Ref
 +
===Outputs===
 +
*Unipolar
 +
*Bipolar
 +
===Settings===
 +
*Coarse Gain
 +
*Fine Gain
 +
*Uni Shaping
 +
*Shaping Time
 +
*PZ
 +
*BLR
 +
*Input
 
==Ortec 871 Timer Counter==
 
==Ortec 871 Timer Counter==
 +
===Purpose===
 +
Count the signal pulses.
 +
===Inputs===
 +
*Positive
 +
*Negative
 +
===Outputs===
 +
*None
 +
===Settings===
 +
*Base Coefficient
 +
*Power
 +
*Time Base
 +
*Dwell
 
==CAEN N110 Dual Attenuator==
 
==CAEN N110 Dual Attenuator==
 +
===Purpose===
 +
Attenuate the signal into a useful region.
 +
===Inputs===
 +
*In
 +
===Outputs===
 +
*Out
 +
===Settings===
 +
*None
 
==CAEN N841 Leading Edge Discriminator==
 
==CAEN N841 Leading Edge Discriminator==
 +
===Purpose===
 +
Distinguish between signal and noise.
 +
===Inputs===
 +
*Channels 0-15
 +
===Outputs===
 +
*Channels 0-15 (NIM Logic Pulse)
 +
===Settings===
 +
*Threshold
 +
*Pulse Width
 
==CAEN N93B Dual Timer==
 
==CAEN N93B Dual Timer==
 +
===Purpose===
 +
Provide dead time to prevent double counting.
 +
===Inputs===
 +
*Start
 +
*Veto
 +
===Outputs===
 +
*Out
 +
===Settings===
 +
*Coarse Pulse Width
 +
*Fine Pulse Width
 
==Tektronic DPO 4104 Digital Phosphor Oscilloscope==
 
==Tektronic DPO 4104 Digital Phosphor Oscilloscope==
 
+
===Purpose===
 +
View hits / troubleshoot system.
 +
===Inputs===
 +
*Channels 1-4
 +
===Outputs===
 +
*None
 +
===Settings===
 +
*Too many to put here.
 
=Flowchart=
 
=Flowchart=
 
[[File:DAF_He3_Tube_Plateau_Study_Hardware_Flowchart.png|800px]]
 
[[File:DAF_He3_Tube_Plateau_Study_Hardware_Flowchart.png|800px]]

Revision as of 20:35, 19 June 2018

Hardware List

He3 tube

Purpose

Neutron Detector. Provides the signal of interest.

Inputs

  • None

Outputs

  • Signal

Settings

  • None

Ortec 142PC Preamplifier

Purpose

Amplifies the signal above the noise level.

Inputs

  • Power
  • Signal
  • Bias

Outputs

  • Time Signal
  • Energy Signal

Settings

  • None

Ortec 459 Bias Supply

Purpose

Provides the bias voltage to the preamp.

Inputs

  • None

Outputs

  • Bias Supply

Settings

  • Output Voltage

Ortec 672 Spectroscopy Amplifier

Purpose

Amplify, shape, and invert the signal.

Inputs

  • Norm
  • Diff Ref

Outputs

  • Unipolar
  • Bipolar

Settings

  • Coarse Gain
  • Fine Gain
  • Uni Shaping
  • Shaping Time
  • PZ
  • BLR
  • Input

Ortec 871 Timer Counter

Purpose

Count the signal pulses.

Inputs

  • Positive
  • Negative

Outputs

  • None

Settings

  • Base Coefficient
  • Power
  • Time Base
  • Dwell

CAEN N110 Dual Attenuator

Purpose

Attenuate the signal into a useful region.

Inputs

  • In

Outputs

  • Out

Settings

  • None

CAEN N841 Leading Edge Discriminator

Purpose

Distinguish between signal and noise.

Inputs

  • Channels 0-15

Outputs

  • Channels 0-15 (NIM Logic Pulse)

Settings

  • Threshold
  • Pulse Width

CAEN N93B Dual Timer

Purpose

Provide dead time to prevent double counting.

Inputs

  • Start
  • Veto

Outputs

  • Out

Settings

  • Coarse Pulse Width
  • Fine Pulse Width

Tektronic DPO 4104 Digital Phosphor Oscilloscope

Purpose

View hits / troubleshoot system.

Inputs

  • Channels 1-4

Outputs

  • None

Settings

  • Too many to put here.

Flowchart

DAF He3 Tube Plateau Study Hardware Flowchart.png