Difference between revisions of "Linac Run Plan April 2018, Dr. McNulty"

From New IAC Wiki
Jump to navigation Jump to search
Line 68: Line 68:
  
 
==[[Absorbed Dose Information]]==
 
==[[Absorbed Dose Information]]==
 
==Quartz==
 
  
 
==Quartz==
 
==Quartz==

Revision as of 18:09, 16 April 2018

Date

85 useable OSLs

Machine: 24b Linac

Beam Energy: 8 MeV

Rep Rate: Max (180Hz)?

Shot # Start Time End Time Number of OSLs Distance to end of beampipe Beam Current Aluminum Brick Background Subtracted PMT Counts
1 7am 7:15am 1 25cm amps Out
2 7:20am 7:35am 1 25cm amps Out
3 7:40am 7:55am 1 25cm amps Out
4 8:00 8:20 1 25cm amps Out
5 1 25cm amps Out
6 1 25cm amps In
7 1 25cm amps In
8 1 25cm amps In
9 1 25cm amps In
10 1 25cm amps In
11 10 25cm amps Out
12 10 25cm amps Out
13 10 25cm amps Out
14 10 25cm amps Out
15 10 25cm amps Out
16 10 25cm amps In
17 15 25cm amps In

Calculations

Assuming 100mApulse and a pulse width of 100ns

Then 100mApulse=100mCspulse=0.1Cspulse

0.1Cspulse(100ns)=10109Cpulse

10109Cpulse1 e1.6021019=6.24221010epulse

OSL Crystal density=3.9698gcm3

Mass of a single OSL crystal: (π(0.501)2(0.03))(3.9698)=0.0234777g

Quartz density=2.32gcm3

Mass of Quartz used in simulation: (π(1.27)2(2.54))(2.32)=29.8593g

Absorbed Dose Information

Quartz

11000 of a pulse. ~62mil e- simulated, ~62bil e- per pulse. With beam parameters given above.

Deposited Energy: 4.71875e+08 MeV



Thesis