Difference between revisions of "170048 10% Se Soil Mixture Analysis"

From New IAC Wiki
Jump to navigation Jump to search
Line 1: Line 1:
 
Sample 170048 was a 10% mixture of selenium and soil. The mass of the inner selenium is 0.5145g, while the mass of the outer selenium is 0.1245g. The method used was the thin window analysis method as explained here [[LB Thesis Thin Window Analysis]]. Below is a table of values to continue with the analysis of the selenium soil mixture:  
 
Sample 170048 was a 10% mixture of selenium and soil. The mass of the inner selenium is 0.5145g, while the mass of the outer selenium is 0.1245g. The method used was the thin window analysis method as explained here [[LB Thesis Thin Window Analysis]]. Below is a table of values to continue with the analysis of the selenium soil mixture:  
  
 +
 +
{| border="3"  cellpadding="5" cellspacing="0"
 +
|| ||  0<t<500 || 1210<t<1750 || 2430<t<2930 || 3616<t<3831
 +
|-
 +
||Thin Window Histogram ||[[]]
 +
|-
 +
||Expanded Window Histogram ||
 +
|-
 +
||Signal in Thin Window || <math> 8.881 \times 10^4 </math> || <math> 8.008 \times 10^4 </math> ||<math> 6.033 \times 10^4 </math> || <math> 2.033 \times 10^4 </math>
 +
|-
 +
||Signal in Expanded Window ||<math> 1.15 \times 10^4 </math> || <math> 9.739 \times 10^4 </math> || 7.2 \times 10^4 </math> || <math> 2.403 \times 10^4 </math>
 +
|-
 +
||<math> S_{Expanded} - S_{Thin} </math>|| 26190 || 17310 || 11670 || 3700
 +
|-
 +
||Integrated Background || 15358 +/- 82 || 9770 +/- 64.8 || 6204 +/- 51.8 || 2110 +/- 30
 +
|-
 +
||Signal - Background || <math> 7.3452 \times 10^4 \pm 2.6190 \times 10^4 </math> || <math> 7.0310 \times 10^4 \pm 1.7310 \times 10^4 </math> || 5.4126 \times 10 ^4 \pm 1.1670 \times 10^4 </math> || <math> 1.8220 \times 10^4 \pm 0.370012 \times 10^4 </math>
 +
|-
 +
||Runtime (s) || 500 || 540 || 500 || 215
 +
|-
 +
||Rate (Hz) || 146.9 +/- 52.38 || 130.20 +/- 32.06 || 108.25 +/- 22.34 || 84.74 +/- 17.21
 +
|-
 +
||Integral Decay Correction (Hz) || 154.43 +/- 55.06 || 137.47 +/- 33.84 || 113.80 +/- 24.43 || 86.59 +/- 17.59
 +
|-
 +
||Dead Time (%) || 6.59 +/- 0.43 || 3.95 +/- 0.42 || 2.26 +/- 0.33 || 1.65 +/- 0.34
 +
|-
 +
||Dead Time Corrected Signal (Hz) || 165.32 +/- 58.95 || 143.12 +/- 35.24 || 116.43 +/- 25.00 || 88.04 +/- 17.89
 +
|-
 +
||.Dat File Entry For HL Plot || 5.11 +/- 0.36 || 4.96 +/- 0.25 || 4.76 +/- 0.21 || 4.48 +/- 0.20 
 +
|}
 +
 +
 +
Below is a table for the pure selenium sample outside of the aluminum cylinder:
  
 
{| border="3"  cellpadding="5" cellspacing="0"
 
{| border="3"  cellpadding="5" cellspacing="0"

Revision as of 21:47, 13 February 2018

Sample 170048 was a 10% mixture of selenium and soil. The mass of the inner selenium is 0.5145g, while the mass of the outer selenium is 0.1245g. The method used was the thin window analysis method as explained here LB Thesis Thin Window Analysis. Below is a table of values to continue with the analysis of the selenium soil mixture:


0<t<500 1210<t<1750 2430<t<2930 3616<t<3831
Thin Window Histogram [[]]
Expanded Window Histogram
Signal in Thin Window [math] 8.881 \times 10^4 [/math] [math] 8.008 \times 10^4 [/math] [math] 6.033 \times 10^4 [/math] [math] 2.033 \times 10^4 [/math]
Signal in Expanded Window [math] 1.15 \times 10^4 [/math] [math] 9.739 \times 10^4 [/math] 7.2 \times 10^4 </math> [math] 2.403 \times 10^4 [/math]
[math] S_{Expanded} - S_{Thin} [/math] 26190 17310 11670 3700
Integrated Background 15358 +/- 82 9770 +/- 64.8 6204 +/- 51.8 2110 +/- 30
Signal - Background [math] 7.3452 \times 10^4 \pm 2.6190 \times 10^4 [/math] [math] 7.0310 \times 10^4 \pm 1.7310 \times 10^4 [/math] 5.4126 \times 10 ^4 \pm 1.1670 \times 10^4 </math> [math] 1.8220 \times 10^4 \pm 0.370012 \times 10^4 [/math]
Runtime (s) 500 540 500 215
Rate (Hz) 146.9 +/- 52.38 130.20 +/- 32.06 108.25 +/- 22.34 84.74 +/- 17.21
Integral Decay Correction (Hz) 154.43 +/- 55.06 137.47 +/- 33.84 113.80 +/- 24.43 86.59 +/- 17.59
Dead Time (%) 6.59 +/- 0.43 3.95 +/- 0.42 2.26 +/- 0.33 1.65 +/- 0.34
Dead Time Corrected Signal (Hz) 165.32 +/- 58.95 143.12 +/- 35.24 116.43 +/- 25.00 88.04 +/- 17.89
.Dat File Entry For HL Plot 5.11 +/- 0.36 4.96 +/- 0.25 4.76 +/- 0.21 4.48 +/- 0.20


Below is a table for the pure selenium sample outside of the aluminum cylinder:

0<t<500 1210<t<1750 2430<t<2930 3616<t<3831
Thin Window Histogram [[]]
Expanded Window Histogram
Signal in Thin Window [math] 8.881 \times 10^4 [/math] [math] 8.008 \times 10^4 [/math] [math] 6.033 \times 10^4 [/math] [math] 2.033 \times 10^4 [/math]
Signal in Expanded Window [math] 1.15 \times 10^4 [/math] [math] 9.739 \times 10^4 [/math] 7.2 \times 10^4 </math> [math] 2.403 \times 10^4 [/math]
[math] S_{Expanded} - S_{Thin} [/math] 26190 17310 11670 3700
Integrated Background 15358 +/- 82 9770 +/- 64.8 6204 +/- 51.8 2110 +/- 30
Signal - Background [math] 7.3452 \times 10^4 \pm 2.6190 \times 10^4 [/math] [math] 7.0310 \times 10^4 \pm 1.7310 \times 10^4 [/math] 5.4126 \times 10 ^4 \pm 1.1670 \times 10^4 </math> [math] 1.8220 \times 10^4 \pm 0.370012 \times 10^4 [/math]
Runtime (s) 500 540 500 215
Rate (Hz) 146.9 +/- 52.38 130.20 +/- 32.06 108.25 +/- 22.34 84.74 +/- 17.21
Integral Decay Correction (Hz) 154.43 +/- 55.06 137.47 +/- 33.84 113.80 +/- 24.43 86.59 +/- 17.59
Dead Time (%) 6.59 +/- 0.43 3.95 +/- 0.42 2.26 +/- 0.33 1.65 +/- 0.34
Dead Time Corrected Signal (Hz) 165.32 +/- 58.95 143.12 +/- 35.24 116.43 +/- 25.00 88.04 +/- 17.89
.Dat File Entry For HL Plot 5.11 +/- 0.36 4.96 +/- 0.25 4.76 +/- 0.21 4.48 +/- 0.20