Difference between revisions of "LB Feb Nickel Consistency Check"
Line 81: | Line 81: | ||
||Thin Window | ||Thin Window | ||
|- | |- | ||
− | ||Original Window || | + | ||Original Window || [[File:R5923 FrontNi Foil OGWindow.png|100px]] || [[File:R5931 FrontFoil Spec OGWindow.png|100px]] ||[[File:R5989 FrontFoil Spec OGWindow.png|100px]] || [[File:R6008 FrontFoil Spec OGWindow.png|100px]] ||[[File:R6026 FrontFoil Spec OGWindow.png|100px]] ||[[File:R6062 FrontFoil OGWindow.png|100px]] || [[File:R6080 FrontFoil OGWindow.png|100px]] ||[[File:R6113 FrontFoil OGWindow.png|100px]] ||[[File:R6138 FrontFoil OGWindow.png|100px]] || [[File:R6146 FrontFoil OGWindow.png|100px]] ||[[File:R6156 FrontFoil OGWindow.png|100px]] |
|- | |- | ||
− | ||Expanded Window || | + | ||Expanded Window || [[File:R5923 FrontNi Spect ExpWindow.png|100px]] || [[File:R5931 FrontFoil Spec ExpWindow.png|100px]] || [[File:R5989 FrontFoil Spec ExpWindow.png|100px]] || [[File:R6008 FrontFoil Spec ExpWindow.png|100px]] || [[File:R6026 FrontFoil Spec ExpWindow.png|100px]] || [[File:R6062 FrontFoil ExpWindow.png|100px]] ||[[File:R6080 FrontFoil ExpWindow.png|100px]] || [[File:R6113 FrontFoil ExpWindow.png|100px]] || [[File:R6138 FrontFoil ExpWindow.png|100px]] || [[File:R6146 FrontFoil ExpWindow.png|100px]] || [[File:R6156 FrontFoil ExpWindow.png|100px]] |
|- | |- | ||
||Maximum of Histogram || | ||Maximum of Histogram || |
Revision as of 17:49, 9 November 2017
This analysis was done on Inv # 170010 which was irradiated in February 2017 with a rotating sample holder. This was a 50% mix of Se and Soil. The mass of the front nickel foil was 0.27 grams and the mass of the rear nickel foil was 0.25 grams. The histograms made were weighted by the time of the run and the mass of the nickel foil.
Below is a table for the front nickel foil:
Below is a table for the rear nickel foil:
Since the efficiency is unknown I will plot the ratio of the activities so the efficiency cancels out. Below is a table of rations that will be entered into a .dat File after correcting for time to make sure that they are the activities at the same time. The decay constant for Ni-57 is
r5924 | r5932 | r5990 | r6009 | r6027 | r6063 | r6081 | r6114 | r6139 | r6147 | r6157 | |
Time elapsed (Sec) | 751 | 761 | 681 | 835 | 630 | 657 | 731 | 981 | 976 | 1337 | 1297 |
Original Activity | 195.99 +/- 9.47 | 290.69 +/- 8.97 | 365.74 +/- 12.01 | 224.17 +/- 9.30 | 274.4 +/- 7.68 | 342.25 +/- 8.00 | 153.54 +/- 8.38 | 147.03 +/- 8.18 | 100.92 +/- 6.76 | 89.94 +/- 13.04 | 34.83 +/- 7.77 |
Corrected Activity (Hz) | 204.12 +/- 9.86 | 302.91 +/- 9.35 | 379.46 +/- 12.46 | 234.53 +/- 9.73 | 283.91 +/- 7.94 | 354.63 +/- 8.29 | 159.73 +/- 8.72 | 155.04 +/- 8.62 | 106.39 +/- 7.13 | 96.69 +/- 14.02 | 37.36 +/- 8.33 |
Ratio With Front Foil | 0.85 +/- 0.07 | 0.64 +/- 0.03 | 0.59 +/- 0.03 | 0.57 +/- 0.04 | 0.50 +/- 0.03 | 0.68 +/- 0.03 | 0.95 +/- 0.07 | 0.67 +/- 0.06 | 0.66 +/- 0.07 | 0.46 +/- 0.08 | 0.64 +/- 0.17 |
Thin Window Method
It would seem according to Se170063 Thin Window Analysis, the thin window method can give answers that we would expect, so I will try that here to see if I can get the ratio of the front and rear nickel foils to be 1.
Below is a table for the front foil information: