Difference between revisions of "LB Feb Nickel Consistency Check"
Jump to navigation
Jump to search
Line 42: | Line 42: | ||
||Signal in Window (Hz)|| 231.6 +/- 7.356 || 318.7 +/- 7.242 || 403.1 +/- 10.34 ||271.6 +/- 6.24 || 302.2 +/- 5.59 | ||Signal in Window (Hz)|| 231.6 +/- 7.356 || 318.7 +/- 7.242 || 403.1 +/- 10.34 ||271.6 +/- 6.24 || 302.2 +/- 5.59 | ||
|- | |- | ||
− | ||Background Subtracted Signal || 230.89 +/- 7.36 || 318.14 +/- 7.24 || 402.35 +/- 10.34 || 270.65 +/- 6.24 | + | ||Background Subtracted Signal || 230.89 +/- 7.36 || 318.14 +/- 7.24 || 402.35 +/- 10.34 || 270.65 +/- 6.24 || 301.64 +/- 5.59 |
|- | |- | ||
|} | |} | ||
Line 52: | Line 52: | ||
|| 2/14/17 || 2/15/17 || 2/17/17 || 2/18/17 | || 2/14/17 || 2/15/17 || 2/17/17 || 2/18/17 | ||
|- | |- | ||
− | ||1.135822511 +/- 0.059600344 || 1.407450009 +/- 0.0493993294 || 1.617877679 +/- 0.0556251315 || 1.693997622 +/- 0.0802205578 | + | ||1.135822511 +/- 0.059600344 || 1.407450009 +/- 0.0493993294 || 1.617877679 +/- 0.0556251315 || 1.693997622 +/- 0.0802205578 || 1.711723981 +/- 0.0742391918 |
|- | |- | ||
|} | |} |
Revision as of 20:12, 8 November 2017
This analysis was done on Inv # 170010 which was irradiated in February 2017 with a rotating sample holder. This was a 50% mix of Se and Soil. The mass of the front nickel foil was 0.27 grams and the mass of the rear nickel foil was 0.25 grams. The histograms made were weighted by the time of the run and the mass of the nickel foil.
Below is a table for the front nickel foil:
Below is a table for the rear nickel foil:
Since the efficiency is unknown I will plot the ratio of the activities so the efficiency cancels out. Below is a table of rations that will be entered into a .dat File
2/14/17 | 2/15/17 | 2/17/17 | 2/18/17 | |
1.135822511 +/- 0.059600344 | 1.407450009 +/- 0.0493993294 | 1.617877679 +/- 0.0556251315 | 1.693997622 +/- 0.0802205578 | 1.711723981 +/- 0.0742391918 |