Difference between revisions of "09-07-2017"
Jump to navigation
Jump to search
Line 27: | Line 27: | ||
| 6524 ||Integral= 280 pV*s 260 mV peak = 1.1A || '''DU-238 R45020 ''' || 10.5 MeV (1108 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 180 Hz. For detector at 54 degrees, lowered HV from 1450 to 1400 on both tubes. | | 6524 ||Integral= 280 pV*s 260 mV peak = 1.1A || '''DU-238 R45020 ''' || 10.5 MeV (1108 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 180 Hz. For detector at 54 degrees, lowered HV from 1450 to 1400 on both tubes. | ||
|- | |- | ||
− | | 6525 ||Integral= 280 pV*s 260 mV peak = 1.1A || '''DU-238 R45020 ''' || 10.5 MeV (1108 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 180 Hz. For detector at 102 degrees, lowered HV from 1400 to 1350 on bottom tube. | + | | 6525 ||Integral= 280 pV*s 260 mV peak = 1.1A || '''DU-238 R45020 ''' || 10.5 MeV (1108 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 180 Hz. For detector at 102 degrees, lowered HV from 1400 to 1350 on bottom tube. |
− | |||
− | |||
|} | |} | ||
Revision as of 18:37, 7 August 2017
Run list
Run # | Charge/pulse | Target | Configuration | Individual histos + rates | overlayed histos | |
---|---|---|---|---|---|---|
6510 | Integral= pV*s 260 mV peak = 1.1A | Al | 10.5 MeV (1108 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 180 Hz | |||
6511 | Integral= pV*s 260 mV peak = 1.1A | Al | 10.5 MeV (1108 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 180 Hz | |||
6512 | Integral= pV*s 260 mV peak = 1.1A | Al | 10.5 MeV (1108 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 180 Hz | |||
6513-6517 | Integral= pV*s 260 mV peak = 1.1A | Al | 10.5 MeV (1108 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 180 Hz | |||
6518 | Integral= pV*s 260 mV peak = 1.1A | MT | 10.5 MeV (1108 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 180 Hz , Faraday cup in place | |||
6519 | Integral= pV*s 260 mV peak = 1.1A | D20 | 10.5 MeV (1108 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 180 Hz, This D2O target is a vial and not the bottle used previously | |||
6521 | Integral= 255+-15 pV*s 260 mV peak = 1.1A | Al | 10.5 MeV (1108 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 180 Hz | |||
6522 | Integral= 255 pV*s 260 mV peak = 1.1A | MT | 10.5 MeV (1108 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 180 Hz | |||
6523 | Integral= 260 pV*s 260 mV peak = 1.1A | DU-238 R45020 | 10.5 MeV (1108 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 180 Hz | |||
6524 | Integral= 280 pV*s 260 mV peak = 1.1A | DU-238 R45020 | 10.5 MeV (1108 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 180 Hz. For detector at 54 degrees, lowered HV from 1450 to 1400 on both tubes. | |||
6525 | Integral= 280 pV*s 260 mV peak = 1.1A | DU-238 R45020 | 10.5 MeV (1108 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 180 Hz. For detector at 102 degrees, lowered HV from 1400 to 1350 on bottom tube. |