Difference between revisions of "Uniform distribution in Energy and Theta LUND files"

From New IAC Wiki
Jump to navigation Jump to search
Line 12: Line 12:
 
[[File:LUND_Spread.C|Creating uniform LUND files]]
 
[[File:LUND_Spread.C|Creating uniform LUND files]]
  
To ensure that all the electrons simulated in GEMC are Moller electrons, this is made easier by first creating them in the center of mass frame after scattering.  In this frame, the Moller differential cross section is well defined, and can be used to ensure that all particles to be simulated will be Moller electrons.  Due to the fact that GEMC simulations will utilize particle momentum in the lab frame, the LUND files must contain lab frame information.  In addition, all the data given is for 11GeV electrons that have not yet had the chance to interact with the target material.   
+
To ensure that all the electrons simulated in GEMC are Moller electrons, electrons are first creating in the center of mass frame after scattering has occured.  In this frame, the Moller differential cross section is well defined, and can be used to ensure that all particles to be simulated in other frames of reference will be Moller electrons.  Due to the fact that GEMC simulations will utilize particle momentum in the lab frame, this imlies the LUND files must contain lab frame information.  The transformation from CM to lab frame can be done using Lorentz boosts.  In addition, all the data given is for 11GeV electrons that have not yet had the chance to interact with the target material.  This implies that all electrons have the same incident energy in the lab, and as such have a constant value in the CM frame.
  
  
In the lab frame there are 2 degrees of freedom, i.e. <math>P_{\theta}</math> and <math>P_{\phi}</math> .  The number of degrees of freedom can be reduced to 1 degrees of freedom in the center of mass frame of reference since the Moller differential cross section does not rely on <math>\phi</math>.  The simplicity of the center of mass frame for Moller electrons is that the interacting particles have equal energies and equal but opposite momentum vectors.  In such a system where these conditions must be met, the directions of the momentum vectors must be opposite, which reduces the degrees of freedom to one direction.  Since the Moller differential cross-section only relies on <math>\theta</math> in all frames it implies for a given angle <math>\theta</math> we should find the same results for any given angle <math>\phi</math>.   
+
In the lab frame there are 2 degrees of freedom, i.e. <math>P_{\theta}</math> and <math>P_{\phi}</math> .  The number of degrees of freedom can be reduced to 1 degrees of freedom in the center of mass frame of reference since the Moller differential cross section does not rely on <math>\phi</math> and all energies are considered equal in the CM frame.  The simplicity of the center of mass frame for Moller electrons is that the interacting particles have equal energies and equal but opposite momentum vectors.  In such a system where these conditions must be met, the directions of the momentum vectors must be opposite, which reduces the degrees of freedom to one direction.  Since the Moller differential cross-section only relies on <math>\theta</math> in all frames it implies for a given angle <math>\theta</math> we should find the same results for any given angle <math>\phi</math>.   
  
  
Line 28: Line 28:
  
  
The LUND file is created by creating an isotropic distribution of electrons within the Moller center of mass frame of reference after scattering.  These particles are uniformly distributed through the angle theta with respect to the beam line in the range 90-180 in the center of mass frame.  This is initially done at a set angle phi (0 degrees) with respect to the perpendicular components with respect to the beam line.
+
The LUND file is created by creating an isotropic distribution of electrons within the Moller center of mass frame of reference after scattering.  These particles are uniformly distributed through the angle theta with respect to the beam line in the range 90-180 in the center of mass frame.  This is initially done at a set angle phi (0 degrees) with respect to the perpendicular components with respect to the beam line.  In the CM frame, the spacing of the angle theta bins are 0.0001 degrees wide.
  
  

Revision as of 20:04, 27 July 2017

[math]\textbf{\underline{Navigation}}[/math]

[math]\vartriangleleft [/math] [math]\triangle [/math] [math]\vartriangleright [/math]


4.1 Uniform Distribution in Energy and Theta LUND files

File:LUND Spread.C

To ensure that all the electrons simulated in GEMC are Moller electrons, electrons are first creating in the center of mass frame after scattering has occured. In this frame, the Moller differential cross section is well defined, and can be used to ensure that all particles to be simulated in other frames of reference will be Moller electrons. Due to the fact that GEMC simulations will utilize particle momentum in the lab frame, this imlies the LUND files must contain lab frame information. The transformation from CM to lab frame can be done using Lorentz boosts. In addition, all the data given is for 11GeV electrons that have not yet had the chance to interact with the target material. This implies that all electrons have the same incident energy in the lab, and as such have a constant value in the CM frame.


In the lab frame there are 2 degrees of freedom, i.e. [math]P_{\theta}[/math] and [math]P_{\phi}[/math] . The number of degrees of freedom can be reduced to 1 degrees of freedom in the center of mass frame of reference since the Moller differential cross section does not rely on [math]\phi[/math] and all energies are considered equal in the CM frame. The simplicity of the center of mass frame for Moller electrons is that the interacting particles have equal energies and equal but opposite momentum vectors. In such a system where these conditions must be met, the directions of the momentum vectors must be opposite, which reduces the degrees of freedom to one direction. Since the Moller differential cross-section only relies on [math]\theta[/math] in all frames it implies for a given angle [math]\theta[/math] we should find the same results for any given angle [math]\phi[/math].


To ensure that we can produce the Moller differential cross section in the center of mass frame we start with a uniform isotropic distribution of Moller electrons with respect to the scattering angle theta. From this distribution, each particle can be applied an appropriate weight that will result in the differential cross section being reproduced.



The LUND file is created by creating an isotropic distribution of electrons within the Moller center of mass frame of reference after scattering. These particles are uniformly distributed through the angle theta with respect to the beam line in the range 90-180 in the center of mass frame. This is initially done at a set angle phi (0 degrees) with respect to the perpendicular components with respect to the beam line. In the CM frame, the spacing of the angle theta bins are 0.0001 degrees wide.





[math]\textbf{\underline{Navigation}}[/math]

[math]\vartriangleleft [/math] [math]\triangle [/math] [math]\vartriangleright [/math]