Difference between revisions of "05-2-2017"
Jump to navigation
Jump to search
(2 intermediate revisions by the same user not shown) | |||
Line 12: | Line 12: | ||
|} | |} | ||
− | |||
− | |||
− | |||
He-3 timing is in patch panel 223A16, & energy is 223A17. | He-3 timing is in patch panel 223A16, & energy is 223A17. | ||
Line 26: | Line 23: | ||
Small aux. scintillators have a CFD threshold of 0.550 V for run 6274 and later. | Small aux. scintillators have a CFD threshold of 0.550 V for run 6274 and later. | ||
+ | |||
+ | |||
+ | =run list= | ||
+ | |||
{| border="1" | {| border="1" | ||
Line 56: | Line 57: | ||
+ | =Analysis= | ||
+ | [[Analysis_of_may_2017_runs]] | ||
Latest revision as of 00:12, 16 June 2017
The He-3 detector output from the spec amp to the ADC had the wrong polarity
Electronics map for the two auxiliary scintillators
Phi Angle (Degrees) | PMT distance | Signal cable label | HV cable label | HV channel on Lecroy Mainframe | CFD CH | VNIM-ECL channel | ROOT variable |
---|---|---|---|---|---|---|---|
~282 | m | 102B1.2 | shv1.2 | 5:L1.2 | 1 | (left) B-0 | evt.TDC[1][25] |
~282 | m | 282T1.7 | shv1.7 | 5:L1.7 | 2 | (left) B-1 | evt.TDC[1][26] |
He-3 timing is in patch panel 223A16, & energy is 223A17.
High voltage & discriminator settings:
30T: 1450;30 , 30B:1450;30 , 54T: 1500;30 , 54B: 1500;30 , 78T:1500;30 , 78B: 1525;30 , 126T: 1500;30 , 126B: 1500;30 , 150T: 1500;40 , 150B: 1500;40 , 210T: 1500;40 , 210B: 1500;40 , 234T: 1500;30 , 234B: 1500;30 , 258T: 1350;30, 258B: 1450;30 , 306T: 1400;30 , 306B: 1400;30 , 330T: 1450;30 , 330B: 1500;30
Radiator 1.5" Al.
Slits currently at 500 => 19 mm, at 75 =0, at 1000=38 mm, readback number is linear with slit width.
Small aux. scintillators have a CFD threshold of 0.550 V for run 6274 and later.
run list
Analysis