Difference between revisions of "He3Tube Equipment"

From New IAC Wiki
Jump to navigation Jump to search
 
(128 intermediate revisions by 3 users not shown)
Line 1: Line 1:
He3 Tube neutron detectors, 1200 Volts with EG&G (ortec) pre amp Model 142PC (Serial #787)
+
[[2nCor_44#Equipment]]
 +
 
 +
=Analog Signals=
 +
 
 +
He3 Tube neutron detectors are 52 cm long and 1.5 cm radius cylinders, 1200 Volts with EG&G (ortec) pre amp Model 142PC (Serial #787)
 +
 
 +
Although 1200 Volts is applied to the Ortec Preamp, only 350 Volts is established on the "input" port where the Tube is plugged in. If 1250 Volts is applied, then 366 Volts is observed.
  
 
[[File:He3Signal_NoSource_4-2017.png | 300 px]]
 
[[File:He3Signal_NoSource_4-2017.png | 300 px]]
 +
 +
For the TENNELEC you need to apply 1650 Volts to get 362 applied to the Tube
 +
 +
 +
The TENNELEC signal output at 1550 Volts has less noise with signal at about 30 mV compared to the output of the ortec. There is a230 mV DC offset on the output
 +
[[File:He3Signal_NoSource_4-6-2017.png | 300 px]]
 +
 +
=Output measured by CAEN V785N Peaks sensing ADC=
 +
 +
Using a Cf-252 source positions on a shelf below the He-3 tube covered by 2" thick virgin Poly and set to 1250 Volts.  Using Ortec pre-amp 142PC serial # 787.
 +
 +
The Timing output of the preamp was sent to an Ortec Timing filter amplifier to be inverted.  The Gain was set to x10 and the integrate set to 20 ns.
 +
 +
The Energy output was sent to an Ortec Spectroscopy amplifier model 672.  The gain was set to x10  and the shaping time set to 2usec.
 +
 +
Run 6245 has a Cf-252 source place on a shelf approximately 80 cm below the He-3 tube that had been encased in 2" thick virgin poly.
 +
 +
Run 6246 recorded the background observed without the source over a 19 hour period.
 +
 +
[[File:He3Signal_Cf-252_4-12-2017.png | 300 px]]
 +
 +
The expectation from  [[File:GE_ReuterStokes.pdf]] is
 +
 +
[[File:ReuterStokeADCspectrum_4-12-17.png | 300 px]]
 +
 +
Performed another measurement of the He-3 tube using the Cf-252 source.  I used the bipolar output of the ORTEC spec AMP model 672.  The He-3 tube is surrounded by a 2" thick layer of virgin poly.  The virgin poly is then encased in a 2" layer of lead.  The  Cf-252 source was placed directly on top of the lead.  Below is a measurement recorded in run #6295 taken over a 7 minute period Run #6596 was taken over a three day period.
 +
 +
If I normalize the rate per cm^2 of detector (project the cylinder to a 52 cm x 3 cm rectangle = 156 cm^2)
 +
 +
[[File:He3Signal_Cf-252_5-12-2017.png | 300 px]]
 +
 +
Cosmic rays produce 10^{3}/cm^2/sec
 +
 +
PAA->Draw("PADC785N[3]>>r6296N(500,0,1000)",".00000002473");
 +
 +
PAA->Draw("PADC785N[3]>>r6295N(500,0,1000)",".000015263");
 +
 +
=Beam Tests=
 +
 +
5/16/17:  44 MeV machine was being tuned at 2 MeV so I used the nCorHe3 configuration to look at the He-3 output when there '''shouldn't be neutrons in the Hall'''. 
 +
 +
Run 6297: Timing AMp =2 Postamp to PADC set to gain of 10
 +
 +
Run 6298: Timing AMp=2 Postamp to PADC set to gain of 50
 +
 +
Run 6299: Timing AMp=adjusting during run Postamp to PADC set to gain of 50
 +
 +
Run 6300: Timing AMp=8 Postamp to PADC set to gain of 50
 +
 +
'''A CFD threshold of -181 mV will keep the He-3 tube timing amp from firing when the 44 MeV machine is running'''.  The Cf-252 source rate was 200 +/- 40 Hz at this CFD setting.
 +
 +
For ADC do
 +
 +
FF->Draw("PADC.PADC785N[3]>>(500,0,1000)");
 +
 +
For TDC (Window is 1500 nsec wide)
 +
 +
FF->Draw("(TDC.TDC1190[1][28]-TDC.TDC1190[1][31])*0.1")
 +
 +
Check Timing with
 +
FF->Draw("(TDC.TDC1190[2][31]-TDC.TDC1190[1][31])*0.1")
 +
 +
The above should be about 200 ns
 +
 +
 +
Run 6301, ran in PAA configuration with Cf 252 source on top of detector
 +
 +
PAA->Draw("PADC.PADC785N[3]>>r6301(2000,0,2000)")
 +
 +
[[File:r6301-6300_He3.png| 200 px]]
 +
 +
 +
 +
==5/23/17==
 +
 +
32 MeV Beam 50 mA current
 +
 +
The He-3 tube is plugged into a scaler that counts all pulses (not just the ones during the beam gate).
 +
 +
 +
 +
{| border="3"  cellpadding="5" cellspacing="0"
 +
|  Run# || Configuration
 +
|-
 +
|6310 || 710 +/- 20 Hz neutron rate during first 15 minutes, then 870 +/- 20 Hz neutron rate during second 15 minutes,  UV broadband pass filter
 +
|-
 +
|6311 || 840 +/- 20 Hz neutron rate during first 15 minutes, then  Hz neutron rate during second 15 minutes,  390 nm Filter
 +
|-
 +
|6313 || 390 nm Filter, HV = 1800 ( the HV has changed from run 6311)
 +
|-
 +
|6314 || 320 nm Filter
 +
|-
 +
|6315 || 320 + 330 nm Filter
 +
|-
 +
|}
 +
 +
the He-3 rate definitely increases during the irradiation (probably due to Hall Activity increasing)
 +
 +
==5/24/17==
 +
 +
32 MeV Beam 150 mA current  100 ns wide beam no beam stop, 4 mm thick (12 g) Yttrium in.
 +
 +
The He-3 tube is plugged into a scaler that counts all pulses (not just the ones during the beam gate).
 +
 +
2.54 mm Tungsten radiator
 +
 +
{| border="3"  cellpadding="5" cellspacing="0"
 +
|  Run# || Configuration
 +
|-
 +
|6318 || '''390''' nm Pass filter, two peaks due to change in current, radiator in
 +
|-
 +
|6319 || '''320''' nm Pass filter, radiator in, ADC channel 500
 +
|-
 +
|6320 || '''390''' nm Pass filter, signal at ADC channel 500, radiator in
 +
|-
 +
|6321 || 390 nm Pass filter, signal at ADC channel 500, radiator '''OUT''', [[File:TellerLight_390nm_5-24-17.png | 200 px]]
 +
|-
 +
|6322 || '''320 nm''' Pass filter, signal at ADC channel 500, radiator OUT, peak at ADC chan 3200 like 390 nm filter
 +
|-
 +
|6323 || "cold air humidifier ON', 320 nm Pass filter, signal at ADC channel 500, radiator OUT, peak at ADC chan 3200 like 390 nm filter, [[File:TellerLight_6323_320nm_5-24-17.png | 200 px]]
 +
|-
 +
|6324 || cold air humidifier '''OFF''', 320 nm Pass filter, signal at ADC channel 500, radiator OUT,
 +
|-
 +
|6325 || cold air humidifier '''ON''', 320 nm Pass filter, signal at ADC channel 500, radiator OUT, beam current 150 mV in 1 Meg Ohm
 +
|-
 +
|6326 || cold air humidifier '''OFF''', 320 nm Pass filter, signal at ADC channel 500, radiator OUT, beam current 150 mV in 1 Meg Ohm, [[File:TellerLight_6326_320nm_5-24-17.png | 200 px]]
 +
|}
 +
 +
the He-3 rate definitely increases during the irradiation (probably due to Hall Activity increasing)
 +
==5/25/17==
 +
 +
32 MeV Beam 150 mA current  100 ns wide beam no beam stop
 +
 +
The He-3 tube is plugged into a scaler that counts all pulses (not just the ones during the beam gate).
 +
 +
{| border="3"  cellpadding="5" cellspacing="0"
 +
|  Run# || Configuration
 +
|-
 +
|6346 || '''320''' nm Pass filter
 +
|-
 +
|6347 || '''320''' nm Pass filter, changed pulse width between 100 and 800 ns
 +
|-
 +
|6348 || 320 nm Pass filter, change amplitude
 +
|-
 +
|6353 ||'''320 nm Pass filter plus UV filter PMT small aperture in the hole, change beam current from 100 to 200 to check normalization'''
 +
|-
 +
|6354 || '''320''' nm Pass filter, plus UV filter PMT small aperture in the hole
 +
|-
 +
|6355 || '''320 & 330''' nm Pass filter, plus UV filter PMT small aperature in the hole
 +
|-
 +
|6356 || '''390''' nm Pass filter, plus UV filter PMT small aperture in the hole,  [[File:TellerLight_6356_5-25-17.png | 200 px]]
 +
|-
 +
|6357 || '''390''' nm Pass filter, plus UV filter PMT small aperture in the hole, No change
 +
|-
 +
|6358 || '''390+320''' nm Pass filter, plus UV filter PMT small aperture in the hole,
 +
|-
 +
|6359 || '''390''' nm Pass filter, plus UV filter PMT small aperture in the hole, Reproducibility check
 +
|-
 +
|6360 || 390 nm Pass filter, plus UV filter PMT small aperture in the hole, increase current from 150 to 200 mA
 +
|-
 +
|6361 || 390 nm Pass filter, plus UV filter PMT small aperture in the hole,  current  150 mA, mister '''ON'''
 +
|-
 +
|6362 || 390 nm Pass filter, plus UV filter PMT small aperture in the hole,  current  150 mA, mister '''OFF'''
 +
|}
 +
 +
 +
==PMT linearity test==
 +
 +
PMT[5] = PMT in the cell looking at the mirror
 +
 +
Suspect PMT was linearly responding to beam current at 50 ns widths and 75 mA peak, 32 MeV
 +
 +
{| border="3"  cellpadding="5" cellspacing="0"
 +
|  Run# || Current (nV*sec) ||  PMT[5](PADC chann #) || PMT[5] Fstop
 +
|-
 +
|6377 ||3.8  || ||
 +
|-
 +
|6378 ||'''8.5'''  ||  1600 || Cut wide pulse current in half and shortened pulse to 50 ns, pulse very hard to measure at 50 ns
 +
|-
 +
|6379 ||'''2.2'''  ||837 || current changed during run
 +
|-
 +
|6380 ||'''3.5'''  ||1200 ||  [[File:TelLin_5-25-17.png | 200 px]]
 +
|-
 +
|6381 || 4.3|| 704|| Position 1=open, at position '''3''', diameter = 26 mm
 +
|-
 +
|6382 || 4.5||190 || Position 1=open, at position '''6''' diameter=3.5 mm
 +
|-
 +
|6383 ||4.7 ||1214 || Position 1=open, at position '''1''' diameter = 31 mm
 +
|-
 +
|6384 || ||1237 || Position 1=open, at position 1, double width to 100 ns
 +
|-
 +
|6385 || ||1237 || Position 1=open, at position 1, double width to 200 ns (ADC overflow!)
 +
|-
 +
|}
 +
 +
== Current calibration==
 +
Changed beam current using width of the beam
 +
 +
{| border="3"  cellpadding="5" cellspacing="0"
 +
|  Run# || Charge || PADC Chann# || Configuration
 +
|-
 +
|6337 ||<math>10 \times \frac{1.47 \times 10^{-6}}{50} = 0.294</math> uC||3625 <math>\pm</math> 26 ||  current calibration, 1.47 uV*sec in 50 Ohms, 2.2 usec, x10 attenuator
 +
|-
 +
|6338 ||  0.1588 || 2098 <math>\pm</math> 6|| current calibration, 794 nV*sec in 50 Ohms, 1.1 usec, x10 attenuator
 +
|-
 +
|6339 || 0.058  ||1093 <math>\pm</math> 4.7 || current calibration, 429 nV*sec in 50 Ohms, 550 nsec, x10 attenuator
 +
|-
 +
|6340 ||0.0378 || 504<math>\pm</math> 4 || current calibration, 189 nV*sec in 50 Ohms, 225 nsec, x10 attenuator
 +
|-
 +
|6341 ||0.0208  || 342 <math>\pm</math> 3 || current calibration, 104 nV*sec in 50 Ohms, 125 nsec, x10 attenuator
 +
|}
 +
 +
slope=8.53252e-05 +/- 6.47968e-06
 +
y-intercept=-0.0189951 +/- 0.0141188
 +
 +
 +
Micro-Coulombs (uC)
 +
 +
FF->Draw("PADC.PADC785N[1]*8.53252e-05>>r6338(5000,0,1)");
 +
 +
 +
 +
{| border="3"  cellpadding="5" cellspacing="0"
 +
|  Run# || Charge || PADC Chann# || Configuration
 +
|-
 +
|6366 ||<math> \times \frac{330 \times 10^{-9}}{10^6} = 0.294</math> uC||1351 <math>\pm</math> 14 ||  current calibration, 330 \pm 5 uV*sec in 1 Meg Ohms, 2.2 usec,
 +
|-
 +
|6367 ||  || 792 <math>\pm</math> 9|| current calibration, 190 \pm 5  nV*sec in 1 M Ohms, 2.2usec
 +
|-
 +
|6368 ||  || 496 <math>\pm</math> 5 || current calibration, 106 \pm 3  nV*sec in 1 M Ohms, 2.2usec
 +
|-
 +
|6371||  || 1066 <math>\pm</math> 10 || current calibration, 265 \pm 4  nV*sec in 1 M Ohms, 2.2usec
 +
|-
 +
|}
 +
 +
 +
==5/26/17==
 +
 +
32 MeV Beam 150 mA current 
 +
 +
UV wide band filter on cell PMT, Aperature wide open
 +
 +
{| border="3"  cellpadding="5" cellspacing="0"
 +
|  Run# || Cell PMT [5] || FC [7]
 +
|-
 +
|6389 ||3142 || 1509
 +
|-
 +
|6390 || 2231|| 908
 +
|-
 +
|6391 ||1191 || 447
 +
|-
 +
|6392 ||708 || 287  (have full current near end)
 +
|-
 +
|6393 ||2642 || 1147
 +
|-
 +
|6394 ||1605 || 580
 +
|-
 +
|6395 ||1889 || 696 (changed current near end of run)
 +
|-
 +
|6396 ||698 || 279
 +
|-
 +
|6397 ||390 || 183 (changed current near end of run)
 +
|}
 +
 +
 +
filters on cell PMT, NO Aperature, Mixed field (taken during irradiation)
 +
 +
{| border="3"  cellpadding="5" cellspacing="0"
 +
|  Run# || Cell PMT [5] || FC [7] || [5]/[7] || comment
 +
|-
 +
|6401 ||3503 || 1743 || 2.0 ||320 nm filer
 +
|-
 +
|6402 ||110 || 1614 || 0.07 || 330 + 320 nm filters
 +
|-
 +
|6403 ||2972 ||1519 || 1.956 || 390 nm Filter
 +
|}
 +
 +
data below shows two regions of linearity
 +
root [6] FF->Draw("PADC.PADC785N[5]/PADC.PADC785N[7]");
 +
root [7] FF->Draw("PADC.PADC785N[7]","PADC.PADC785N[5]/PADC.PADC785N[7]<2");
 +
root [8] FF->Draw("PADC.PADC785N[7]","PADC.PADC785N[5]/PADC.PADC785N[7]>2");
 +
 +
 +
{| border="3"  cellpadding="5" cellspacing="0"
 +
|  Run# || Cell PMT [5] || FC [7]
 +
|-
 +
|6403 ||2972 ||1519
 +
|-
 +
|6404 || 2017 || 894
 +
|-
 +
|6405 || 1259 || 526
 +
|-
 +
|6406 || 758 || 332
 +
|-
 +
|6407 || 422 || 209
 +
|-
 +
|6408 ||2620 || 1312
 +
|-
 +
|6409 || 1657|| 702
 +
|-
 +
|6410 ||934 || 398
 +
|-
 +
|6411 ||549 || 254
 +
|}
 +
 +
 +
{| border="3"  cellpadding="5" cellspacing="0"
 +
|  Run# || Cell PMT [5] / FC [7] || Mist
 +
|-
 +
|6411 ||2.15 || Off
 +
|-
 +
|6413 || 1.951 ||  ON
 +
|-
 +
|6414 || 1.944 || Off
 +
|-
 +
|6415 || || On
 +
|}
 +
 +
[[2nCor 44| go_back]]
 +
 +
[[2nCor_44#Equipment]]

Latest revision as of 18:41, 26 May 2017

2nCor_44#Equipment

Analog Signals

He3 Tube neutron detectors are 52 cm long and 1.5 cm radius cylinders, 1200 Volts with EG&G (ortec) pre amp Model 142PC (Serial #787)

Although 1200 Volts is applied to the Ortec Preamp, only 350 Volts is established on the "input" port where the Tube is plugged in. If 1250 Volts is applied, then 366 Volts is observed.

He3Signal NoSource 4-2017.png

For the TENNELEC you need to apply 1650 Volts to get 362 applied to the Tube


The TENNELEC signal output at 1550 Volts has less noise with signal at about 30 mV compared to the output of the ortec. There is a230 mV DC offset on the output He3Signal NoSource 4-6-2017.png

Output measured by CAEN V785N Peaks sensing ADC

Using a Cf-252 source positions on a shelf below the He-3 tube covered by 2" thick virgin Poly and set to 1250 Volts. Using Ortec pre-amp 142PC serial # 787.

The Timing output of the preamp was sent to an Ortec Timing filter amplifier to be inverted. The Gain was set to x10 and the integrate set to 20 ns.

The Energy output was sent to an Ortec Spectroscopy amplifier model 672. The gain was set to x10 and the shaping time set to 2usec.

Run 6245 has a Cf-252 source place on a shelf approximately 80 cm below the He-3 tube that had been encased in 2" thick virgin poly.

Run 6246 recorded the background observed without the source over a 19 hour period.

He3Signal Cf-252 4-12-2017.png

The expectation from File:GE ReuterStokes.pdf is

ReuterStokeADCspectrum 4-12-17.png

Performed another measurement of the He-3 tube using the Cf-252 source. I used the bipolar output of the ORTEC spec AMP model 672. The He-3 tube is surrounded by a 2" thick layer of virgin poly. The virgin poly is then encased in a 2" layer of lead. The Cf-252 source was placed directly on top of the lead. Below is a measurement recorded in run #6295 taken over a 7 minute period Run #6596 was taken over a three day period.

If I normalize the rate per cm^2 of detector (project the cylinder to a 52 cm x 3 cm rectangle = 156 cm^2)

He3Signal Cf-252 5-12-2017.png

Cosmic rays produce 10^{3}/cm^2/sec

PAA->Draw("PADC785N[3]>>r6296N(500,0,1000)",".00000002473");

PAA->Draw("PADC785N[3]>>r6295N(500,0,1000)",".000015263");

Beam Tests

5/16/17: 44 MeV machine was being tuned at 2 MeV so I used the nCorHe3 configuration to look at the He-3 output when there shouldn't be neutrons in the Hall.

Run 6297: Timing AMp =2 Postamp to PADC set to gain of 10

Run 6298: Timing AMp=2 Postamp to PADC set to gain of 50

Run 6299: Timing AMp=adjusting during run Postamp to PADC set to gain of 50

Run 6300: Timing AMp=8 Postamp to PADC set to gain of 50

A CFD threshold of -181 mV will keep the He-3 tube timing amp from firing when the 44 MeV machine is running. The Cf-252 source rate was 200 +/- 40 Hz at this CFD setting.

For ADC do

FF->Draw("PADC.PADC785N[3]>>(500,0,1000)");

For TDC (Window is 1500 nsec wide)

FF->Draw("(TDC.TDC1190[1][28]-TDC.TDC1190[1][31])*0.1")

Check Timing with FF->Draw("(TDC.TDC1190[2][31]-TDC.TDC1190[1][31])*0.1")

The above should be about 200 ns


Run 6301, ran in PAA configuration with Cf 252 source on top of detector

PAA->Draw("PADC.PADC785N[3]>>r6301(2000,0,2000)")

R6301-6300 He3.png


5/23/17

32 MeV Beam 50 mA current

The He-3 tube is plugged into a scaler that counts all pulses (not just the ones during the beam gate).


Run# Configuration
6310 710 +/- 20 Hz neutron rate during first 15 minutes, then 870 +/- 20 Hz neutron rate during second 15 minutes, UV broadband pass filter
6311 840 +/- 20 Hz neutron rate during first 15 minutes, then Hz neutron rate during second 15 minutes, 390 nm Filter
6313 390 nm Filter, HV = 1800 ( the HV has changed from run 6311)
6314 320 nm Filter
6315 320 + 330 nm Filter

the He-3 rate definitely increases during the irradiation (probably due to Hall Activity increasing)

5/24/17

32 MeV Beam 150 mA current 100 ns wide beam no beam stop, 4 mm thick (12 g) Yttrium in.

The He-3 tube is plugged into a scaler that counts all pulses (not just the ones during the beam gate).

2.54 mm Tungsten radiator

Run# Configuration
6318 390 nm Pass filter, two peaks due to change in current, radiator in
6319 320 nm Pass filter, radiator in, ADC channel 500
6320 390 nm Pass filter, signal at ADC channel 500, radiator in
6321 390 nm Pass filter, signal at ADC channel 500, radiator OUT, TellerLight 390nm 5-24-17.png
6322 320 nm Pass filter, signal at ADC channel 500, radiator OUT, peak at ADC chan 3200 like 390 nm filter
6323 "cold air humidifier ON', 320 nm Pass filter, signal at ADC channel 500, radiator OUT, peak at ADC chan 3200 like 390 nm filter, TellerLight 6323 320nm 5-24-17.png
6324 cold air humidifier OFF, 320 nm Pass filter, signal at ADC channel 500, radiator OUT,
6325 cold air humidifier ON, 320 nm Pass filter, signal at ADC channel 500, radiator OUT, beam current 150 mV in 1 Meg Ohm
6326 cold air humidifier OFF, 320 nm Pass filter, signal at ADC channel 500, radiator OUT, beam current 150 mV in 1 Meg Ohm, TellerLight 6326 320nm 5-24-17.png

the He-3 rate definitely increases during the irradiation (probably due to Hall Activity increasing)

5/25/17

32 MeV Beam 150 mA current 100 ns wide beam no beam stop

The He-3 tube is plugged into a scaler that counts all pulses (not just the ones during the beam gate).

Run# Configuration
6346 320 nm Pass filter
6347 320 nm Pass filter, changed pulse width between 100 and 800 ns
6348 320 nm Pass filter, change amplitude
6353 320 nm Pass filter plus UV filter PMT small aperture in the hole, change beam current from 100 to 200 to check normalization
6354 320 nm Pass filter, plus UV filter PMT small aperture in the hole
6355 320 & 330 nm Pass filter, plus UV filter PMT small aperature in the hole
6356 390 nm Pass filter, plus UV filter PMT small aperture in the hole, TellerLight 6356 5-25-17.png
6357 390 nm Pass filter, plus UV filter PMT small aperture in the hole, No change
6358 390+320 nm Pass filter, plus UV filter PMT small aperture in the hole,
6359 390 nm Pass filter, plus UV filter PMT small aperture in the hole, Reproducibility check
6360 390 nm Pass filter, plus UV filter PMT small aperture in the hole, increase current from 150 to 200 mA
6361 390 nm Pass filter, plus UV filter PMT small aperture in the hole, current 150 mA, mister ON
6362 390 nm Pass filter, plus UV filter PMT small aperture in the hole, current 150 mA, mister OFF


PMT linearity test

PMT[5] = PMT in the cell looking at the mirror

Suspect PMT was linearly responding to beam current at 50 ns widths and 75 mA peak, 32 MeV
Run# Current (nV*sec) PMT[5](PADC chann #) PMT[5] Fstop
6377 3.8
6378 8.5 1600 Cut wide pulse current in half and shortened pulse to 50 ns, pulse very hard to measure at 50 ns
6379 2.2 837 current changed during run
6380 3.5 1200 TelLin 5-25-17.png
6381 4.3 704 Position 1=open, at position 3, diameter = 26 mm
6382 4.5 190 Position 1=open, at position 6 diameter=3.5 mm
6383 4.7 1214 Position 1=open, at position 1 diameter = 31 mm
6384 1237 Position 1=open, at position 1, double width to 100 ns
6385 1237 Position 1=open, at position 1, double width to 200 ns (ADC overflow!)

Current calibration

Changed beam current using width of the beam

Run# Charge PADC Chann# Configuration
6337 [math]10 \times \frac{1.47 \times 10^{-6}}{50} = 0.294[/math] uC 3625 [math]\pm[/math] 26 current calibration, 1.47 uV*sec in 50 Ohms, 2.2 usec, x10 attenuator
6338 0.1588 2098 [math]\pm[/math] 6 current calibration, 794 nV*sec in 50 Ohms, 1.1 usec, x10 attenuator
6339 0.058 1093 [math]\pm[/math] 4.7 current calibration, 429 nV*sec in 50 Ohms, 550 nsec, x10 attenuator
6340 0.0378 504[math]\pm[/math] 4 current calibration, 189 nV*sec in 50 Ohms, 225 nsec, x10 attenuator
6341 0.0208 342 [math]\pm[/math] 3 current calibration, 104 nV*sec in 50 Ohms, 125 nsec, x10 attenuator

slope=8.53252e-05 +/- 6.47968e-06 y-intercept=-0.0189951 +/- 0.0141188


Micro-Coulombs (uC)

FF->Draw("PADC.PADC785N[1]*8.53252e-05>>r6338(5000,0,1)");


Run# Charge PADC Chann# Configuration
6366 [math] \times \frac{330 \times 10^{-9}}{10^6} = 0.294[/math] uC 1351 [math]\pm[/math] 14 current calibration, 330 \pm 5 uV*sec in 1 Meg Ohms, 2.2 usec,
6367 792 [math]\pm[/math] 9 current calibration, 190 \pm 5 nV*sec in 1 M Ohms, 2.2usec
6368 496 [math]\pm[/math] 5 current calibration, 106 \pm 3 nV*sec in 1 M Ohms, 2.2usec
6371 1066 [math]\pm[/math] 10 current calibration, 265 \pm 4 nV*sec in 1 M Ohms, 2.2usec


5/26/17

32 MeV Beam 150 mA current

UV wide band filter on cell PMT, Aperature wide open

Run# Cell PMT [5] FC [7]
6389 3142 1509
6390 2231 908
6391 1191 447
6392 708 287 (have full current near end)
6393 2642 1147
6394 1605 580
6395 1889 696 (changed current near end of run)
6396 698 279
6397 390 183 (changed current near end of run)


filters on cell PMT, NO Aperature, Mixed field (taken during irradiation)

Run# Cell PMT [5] FC [7] [5]/[7] comment
6401 3503 1743 2.0 320 nm filer
6402 110 1614 0.07 330 + 320 nm filters
6403 2972 1519 1.956 390 nm Filter

data below shows two regions of linearity root [6] FF->Draw("PADC.PADC785N[5]/PADC.PADC785N[7]"); root [7] FF->Draw("PADC.PADC785N[7]","PADC.PADC785N[5]/PADC.PADC785N[7]<2"); root [8] FF->Draw("PADC.PADC785N[7]","PADC.PADC785N[5]/PADC.PADC785N[7]>2");


Run# Cell PMT [5] FC [7]
6403 2972 1519
6404 2017 894
6405 1259 526
6406 758 332
6407 422 209
6408 2620 1312
6409 1657 702
6410 934 398
6411 549 254


Run# Cell PMT [5] / FC [7] Mist
6411 2.15 Off
6413 1.951 ON
6414 1.944 Off
6415 On

go_back

2nCor_44#Equipment