+ | Source neutrons are generated with MCNP-POLIMI CF252 SF generator. The detector is 1.25 meters from the source and the shielding geometry is shown below. The X-axis in the histogram is a distance between 2 points, namely: p1) Linearly extrapolating the neutron's initial direction of travel to intersect with the plane of the detector, and p2) the "actual" location in which the neutron deposited >=0.25 MeV of energy into the scintillator. The result is that on average the shielding scatters the neutrons by only 1". | ||
[[File:DetGeom.png|600px]] | [[File:DetGeom.png|600px]] | ||
Line 5: | Line 8: | ||
[[File:NDeflection.png|770px]] | [[File:NDeflection.png|770px]] | ||
− | |||
Latest revision as of 22:47, 8 March 2017
go back MCNP simulations
Source neutrons are generated with MCNP-POLIMI CF252 SF generator. The detector is 1.25 meters from the source and the shielding geometry is shown below. The X-axis in the histogram is a distance between 2 points, namely: p1) Linearly extrapolating the neutron's initial direction of travel to intersect with the plane of the detector, and p2) the "actual" location in which the neutron deposited >=0.25 MeV of energy into the scintillator. The result is that on average the shielding scatters the neutrons by only 1".
go back MCNP simulations